Datasheet
Table Of Contents
Serie MN
Pinces ampèremetriques pour courant AC
Non-contractual document
906131102C - Ed 1
3.03 (1/1)
Y
N
serie
Current clamp for AC current Current clamp for AC current
ELECTRICAL SPECIFICATIONS
•
Current range:
4 A AC .. 600 A AC
•
Current transformation ratio:
100:1
•
Output signal:
10 mAAC / A AC
•
Accuracy
(1)
:
Primary current 4 A 25 A 100 A 250 A 500 A 600 A
(2)
Accuracy in %
of output signal
5 % + 5 mA 5 % 3 % 3 % 3 % 3 %
Phase shift not specified 6° 5 ° 3° 3° 3°
class 3 at 2.5 VA
(1) Conditions of reference: 23 °C ± 5 °K, 20 % to 75 % RH, 48Hz to 65Hz, external magnetic fi eld <40A/m,
no current-carrying conductor nearby, centred test sample, load impedance 0.1 Ω.
(2) 700 A for 10 minutes max.
•
Bandwidth:
48 Hz .. 1,000 Hz
•
Load impedance:
0.1 Ω max
•
Overload:
700 A for 10 minutes
•
Maximum output voltage (secondary open):
Electronic protection circuit limiting voltage
to 10V peak max
•
Operating voltage:
600V
RMS
•
Common mode voltage:
30V
RMS
•
Infl uence of adjacent and parallel conductors:
<30 mA / A at 50 Hz
•
Infl uence of conductor position in jaws:
±1 %
MECHANICAL SPECIFICATIONS
•
Operating temperature:
15 °C .. +50 °C
•
Storage temperature:
-40 °C .. +85 °C
•
Infl uence of temperature:
<0.1 % per 10 °K
•
Operating altitude:
0 to 2,000 m
•
Max. jaw opening:
33mm
•
Clamping capacity:
Cable: Ømax 30mm
Busbar: 63 x 5mm
•
Casing protection rating:
IP20 in accordance with IEC 529
•
Drop test:
1.5 m (IEC68-2-32)
•
Shock resistance:
100 g, in accordance with IEC68-2-27
•
Vibration resistance:
10 / 55/10 Hz, 0.15mm test in accordance with
IEC68-2-6
•
Self-extinguishing capability:
UL94 V0
•
Dimensions:
66 x 195 x 34mm
•
Weight:
420 g
•
Colour:
Dark grey
•
Output:
1.5 m two-wire lead with double or reinforced
insulation terminated by 2 elbowed male safety
plugs (4 mm)
SAFETY SPECIFICATIONS
•
Electrical safety:
Double or reinforced insulation between the
primary and secondary circuits and the outer
casing in accordance with IEC1010-2-032.
- 600V category III, pollution degree 2
- 300V category IV, pollution degree 2
•
Electromagnetic compatibility (EMC):
EN50081-1: classB
EN50082-2:
- Electrical discharge: IEC1000-4-2
- Radiated field: IEC 1000-4-3
- Fast transients: IEC1000-4-4
- Magnetic field at 50/60 Hz: IEC1000-4-8
Current
500 A AC
Ratio
100 / 1
Output
10 mA / A
To order Reference
AC current clamp model Y3N with operating manual P01120029A
Model Y3N