User Manual
Functional Description
39
3 secondary
measurements
that can be
selected by the
icons
below:
If no display is selected, or if no display is possible (e.g. frequency measurement of a DC
signal, etc.), the string '-----' is displayed.
If the channel is not selected, the string '-X-' is displayed. If the signal is outside of the range:
"OL" for overload is displayed.
Frequency
In the case of an AC amplitude
measurement, display of the frequency
of the signal measured (if possible and
coherent) in each channel.
Statistics
Display of the Min and Max values of the
measurements made in each channel
Relative mode
Display of the difference in each
channel.
This is the difference between the
measured value and the value displayed
when this key was pressed.
4.2.3 Adjustments of the VERTICAL menu
Activation or de-activation of the parameters of channels CH1, CH2, CH3, CH4
independently of one another
Types of parameter according to the Probix connected (adjustment in oscilloscope mode)
Quantity displayed. This depends:
- on the type of measurement selected:
amplitude (available on all channels)
ohmmeter
continuity
capacitance meter
- on the Probix PT100/TK temperature probe (available on all channels)
- on the Probix probe connected to the input
- on the parameters defined in the vertical parameter zone (if they have been modified since
the connection of the Probix probe).
For the ranges available according to the type of measurement, refer to the technical
specifications, "Multimeter" function.
The change of range in manual range is effected by pressing this key.
RUN Start of measurements
HOLD Freeze of the measurement