User Manual
10
10
3.1.4 Resistance measurement
To measure the resistance, proceed as follows:
1. Set the switch to
;
2. Connect the black lead to the COM terminal and the red lead to "+";
3. Place the test probes on the terminals of the component;
Remark: all resistance measurements must be performed with the power off.
4. Read the measurement indicated on the display.
5. "O.L" is displayed if the circuit is open.
3.1.5 Audible continuity measurement
For audible continuity measurement, proceed as follows:
1. Set the switch to
;
2. Press . The symbol is displayed;
3. Connect the black lead to the COM terminal and the red lead to "+";
4. Place the test probes on the terminals of the circuit to be measured;
5. Read the measurement indicated on the display.
6. The continuity beep sounds when R < 30 Ω ± 3 Ω.