Snapshot Vue™ VI Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A. (800) 762-1084 – (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.
TABLE OF CONTENTS 1. BEFORE YOU BEGIN....................................................................................................................................................... 3 WHAT IS INCLUDED ................................................................................................................................................................................ 3 UNPACKING INSTRUCTIONS .....................................................................................................
1. BEFORE YOU BEGIN What is included ¾ ¾ ¾ ¾ 1 x Vue™ VI Power Cord Warranty Card User Manual Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials.
Safety Instructions Please read these instructions carefully, which includes important information about the installation, usage and maintenance of this product. • • • • • • • • • • • • • Caution! Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.
2.
Product Overview Hanging Bracket Tilt Adjustment Knob DMX Input Connector DMX Output Connector Dipswitches Sound Sensitivity Knob Microphone AC Power Input & Fuse Power Output Connector Vue™ VI User Manual 6 2007-12-12/17:23
3. SETUP Disconnect the power cord before replacing a fuse and always replace with the same type fuse. Fuse Replacement With a flat head screwdriver wedge the fuse holder out of its housing. Remove the damaged fuse from its holder and replace with exact same type fuse. Insert the fuse holder back in its place and reconnect power. The fuse is located inside this compartment. Remove using a flat head screwdriver.
CAB LE C ONN ECTORS Cabling must have a male XLR connector on one end and a female XLR connector on the other end. 1 3 2 DMX connector configuration COMMON INPUT 1 3 2 CAUTION 1 3 2 DMX + DMX - Resistance 120 ohm 1/4w between pin 2 (DMX -) and pin 3 (DMX +) of the last fixture. OUTPUT Termination reduces signal errors and to avoid signal transmission problems and interference, it is always advisable to connect a DMX signal terminator.
Stand-Alone/Master/Slave Fixture Linking 1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture. 2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
4. OPERATING INSTRUCTIONS Operation Stand-Alone Mode (Sound-Active, Auto Mode, Strobe Mode, All On): This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto Mode. 1) 2) Set dipswitches position to Sound-Active or Auto Mode.
DMX Mode This mode allows the unit to be controlled by any universal DMX controller. If you are unfamiliar with DMX, please read the DMX Primer on page 16. 1) Set dipswitches 1-9 to the desired DMX address. For help setting the address, see the “SETTING THE STARTING ADDRESS” section on the next page.
Vue™ VI User Manual 075 Ù 079 080 Ù 084 085 Ù 089 090 Ù 094 095 Ù 099 100 Ù 104 105 Ù 109 110 Ù 114 115 Ù 119 120 Ù 124 125 Ù 129 130 Ù 134 135 Ù 139 140 Ù 144 145 Ù 149 150 Ù 154 155 Ù 159 160 Ù 164 165 Ù 169 170 Ù 255 Auto 8 Auto 9 Auto 10 Auto 11 Auto 12 Auto 13 Auto 14 Auto 15 Auto 16 Auto 17 Auto 18 Auto 19 Auto 20 Auto 21 Auto 22 Auto 23 Auto 24 Auto 25 Auto 26 Auto 27 4 000 Ù 004 005 Ù 009 010 Ù 014 015 Ù 019 020 Ù 024 025 Ù 029 030 Ù 034 035 Ù 039 040 Ù 044 045 Ù 049 050 Ù 054 055 Ù 059 060 Ù 06
SETTING THE STARTING ADDRESS This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start address" from 1 to 512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that uses 6 DMX channels and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105.
D MX QU ICK R EFER ENC E CHART DMX Address Quick Reference Chart Dip Switch Position DMX DIP #9 SWITCH SET 0=OFF #8 1=ON #7 X=OFF or ON #6 #1 #2 #3 #4 #5 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 1 1 0 0 0 0 0 1 0 0 1 0 1 0 0 0 1 1 0 0 1 1 1 0 0 0 0 0 1 0 1 0 0 1 0 0 1 0 1 0 1 1 0 1 0 0 0 1 1 0 1 0 1 1 0 0 1 1 1 0 1 1 1 1 0 0 0 0 0 1 1 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 0 1 0 1 1 0 1 0 1 0 1 1 0 1 1 1 1 0 1 0 0 0 1 1 1 0 0 1 1 0 1 0 1 1 1 1 0 1 1 0 0 1 1 1 1 0 1 1 1 0 1 1 1 1 1 1 1 1 1 Dip Switch Position Vue™ VI User Man
General Troubleshooting Applies to Foggers & Snow Dimmers & Chaser Symptom Solution(s) Auto shut off Check fan thermal switch reset 9 Beam is very dim or not bright Clean optical system or replace lamp Check 220/110v switch for proper setting 9 Breaker/Fuse keeps blowing Check total load placed on device Chase is too slow Check users manual for speed adjustment 9 9 9 Device has no power Check for power on Mains. Check device’s fuse.
Technical Support Address: Service Dept. 3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.) Support (Email): tech@chauvetlighting.com Telephone: (954) 929-1115 - (Press 4) Fax: (954) 929-5560 - (Attention: Service) Website: http://www.chauvetlighting.com 5. APPENDIX DMX Primer There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX 512 will require one or a number of sequential channels.
Returns Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return.