Snapshot Use on Dimmer Outdoor Sound Activated DMX Master/Slave 115 V / 230 V Switch Resettable Breaker User Serviceable Duty Cycle User Manual 3000 N 29th Ct, Hollywood, FL 33020 U.S.A. (800) 762-1084 – (954) 929-1115 FAX (954) 929-5560 www.chauvetlighting.
TABLE OF CONTENTS 1. BEFORE YOU BEGIN ................................................................................................................................................... 3 WHAT IS INCLUDED ................................................................................................................................................................................ 3 UNPACKING INSTRUCTIONS ........................................................................................................
1. BEFORE YOU BEGIN What is included 1 x Arena Hazer™ 2 1 x Wired remote 1 x Warranty Card 1 x User Manual Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling.
Safety Instructions Please read these instructions carefully. It includes important information about the installation, usage and maintenance of this product. Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture.
2. INTRODUCTION Features 2-channel DMX professional hazer Adjustable haze output via wired remote or DMX Adjustable blower speed via wired remote or DMX Additional Features Adjustable blower angle 3-pin and 5-pin DMX connections Wired remote with LCD screen 2.
Product Overview Power switch Power in Breaker Carrying handle Wired remote with LCD backlit control panel 3-pin DMX in/out Blower 5-pin DMX in/out LED-illuminated tank Door latch Arena Hazer™ 2 User Manual 6 4/20/2010 4:23 PM
Product Dimensions Arena Hazer™ 2 User Manual 7 4/20/2010 4:23 PM
3. SETUP AC Power This fixture runs on either 115 VAC, 60 Hz, or 230 VAC, 50 Hz. Before powering on the unit, make sure the line voltage to which you are connecting it is within the range of accepted voltages. Always connect the fixture to a switched circuit. Never connect the fixture to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used only as a 0 to 100% switch.
4. OPERATING INSTRUCTIONS Configuring the Starting Address Each fixture requires a starting address from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the starting address. For example, a fixture that uses seven DMX channels and is addressed to start on DMX channel 100, will read data from channels: 100, 101, 102, 103, 104, 105 and 106. Choose the starting addresses for each fixture so that the channels used do not overlap.
Control Panel Functions (cont.) DMX This operating mode will allow you to control the Arena Hazer™ 2 with an external DMX controller. You must set the starting address for this mode. If this is your first time using DMX, then it is recommended that you refer to the “DMX Primer” section in the “Appendix” of this manual. 1. 2. 3. Press . Using + and - buttons, select the desired DMX address. Press .
LED Indicators When the fluid is low in the hazer, the low fluid indicator (shown as NO FLUID on the hazer) will light solid. When the hazer detects DMX signal, the DMX indicator (shown as DMX OK on the hazer) will light solid. Auto Cut-Off Feature This product has a safety feature to keep the machine from becoming damaged. This is referring to the operation of the pump. When the fluid tank is empty, the pump will still operate for a short time until all of the fluid has been removed from the system.
General Troubleshooting SYMPTOM POSSIBLE CAUSE(S) Breaker/Fuse keeps blowing Device does not power up Fixture is not responding to DMX Loss of signal POSSIBLE ACTION(S) Excessive circuit load Check total load placed on the electrical circuit Short circuit along the power wires Check for a short in the electrical wiring (internal and/or external) No power Check for power at power outlet Loose power cord Check power cord Wrong DMX addressing Check Control Panel and unit addressing Damaged DMX
5. APPENDIX DMX Primer There are 512 channels in a DMX connection. Channels may be assigned in any manner. A fixture capable of receiving DMX will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in advance.
Warning! All haze machines are prone to clogging due to the thick consistency of the fog liquid and the high temperature at which it vaporizes. However, a properly maintained fog machine should provide years of reliable use. Cleaning your fog machine regularly will help reduce costly replacement and repair charges. Maintenance Do not allow the haze machine to become contaminated.
Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support. Fixtures on a serial data link must be daisy chained in one single line.
3-Pin to 5-Pin Conversion Chart If you use a controller with a 5-pin DMX output connector, you will need to use a 5-pin to 3-pin adapter. The chart below details a proper cable conversion: 3-PIN TO 5-PIN CONVERSION CHART Conductor 3-Pin Female (Output) 5-Pin Male (Input) Ground/Shield Pin 1 Pin 1 Data ( - ) signal Pin 2 Pin 2 Data ( + ) signal Pin 3 Pin 3 Not used Pin 4 Not used Pin 5 Setting up a DMX Serial Data Link Universal DMX Controller 1.
Returns Procedure Returned merchandise must be sent prepaid and in the original packing; call tags will not be issued. Package must be clearly labeled with a Return Merchandize Authorization Number (RMA #). Products returned without the RMA # will be refused. Call CHAUVET and request an RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return.
Technical Specifications WEIGHT & DIMENSIONS Length ........................................................................................................................ 18.1 in (462 mm) Width.......................................................................................................................... 12.7 in (322 mm) Height ........................................................................................................................ 11.8 in (303 mm) Weight..........................