User manual
Page 10 of 16 Arena™ Hazer 3 User Manual (Rev. 01d)
Configuration (Stand-alone Modes)
Timer Mode
To enable the Timer mode, do the following:
1) Connect this product to a suitable power outlet
2) Turn this product on.
3) Press <FUNCTION> repeatedly until Interval Set shows on the display.
4) Use <UP> or <DOWN> to select the time in between haze.
5) Press <FUNCTION> repeatedly until Duration Set shows on the display.
6) Use <UP> or <DOWN> to select the duration of haze.
7) Press <FUNCTION> repeatedly until Timer Out shows on the display.
8) Use <UP> or <DOWN> to select the volume of haze.
9) Press <FUNCTION> repeatedly until Fan Speed shows on the display.
10) Use <UP> or <DOWN> to select fan speed. Setting this to OFF will disable the
fan in Timer Mode.
11) Press <TIMER> to activate the mode with the above settings.
Volume Mode
To enable the Volume mode, do the following:
1) Connect this product to a suitable power outlet
2) Turn this product on.
3) Press <FUNCTION> repeatedly until Volume Out shows on the display.
4) Use <UP> or <DOWN> to select the volume of haze.
5) Press <FUNCTION> repeatedly until Fan Speed shows on the display.
6) Use <UP> or <DOWN> to select fan speed. Setting this to OFF will disable the
fan in Volume Mode.
7) Press <VOLUME> to activate the mode with the above settings.
DMX Channel Assignments and Values
Channel Function Value Setting
1
Blower
000
ó
255
0~100%
2
Haze
000
ó
255
0~100%