User Manual
TABLE OF CONTENTS 1. Before you Begin ............................................................................ 3 What is Included........................................................................................ 3 Unpacking Instructions .............................................................................. 3 Text Conventions ...................................................................................... 3 Icons ........................................................................
1. BEFORE YOU BEGIN What is Included • • • • 1 x Arena™ Hazer 3 1 x Power Cord 1 x Warranty Card 1 x User Manual Unpacking Instructions Immediately upon receiving this product, carefully unpack it and check the container in which you received it. Make sure that you have received all the parts indicated above and that they are all in good condition.
Product at a Glance Use on Dimmer Outdoor Use Sound Activated DMX Master/Slave x x x P x Auto Programs Auto-ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle x x P x x Safety Notes Please read the following notes carefully because they include important safety information about the installation, usage, and maintenance of this product. Page 4 of 16 • Keep this User Manual for future consultation. If you sell this product to another user, be sure that they also receive this document.
2. INTRODUCTION Product Overview Carrying handle Fluid reservoir cover Haze output nozzle Air filter Rubber feet (4) DMX (3-pin & 5-pin) LCD screen (Control Panel) Power Switch (ON/OFF) Power Input (NEUTRIK® powerCON® A) Main Breaker Arena™ Hazer 3 User Manual (Rev.
3. SETUP AC Power This product uses a transformer-based power supply with a fixed input voltage of either 120 V, 60 Hz or 230 V, 50 Hz. To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating indicates its average current draw under normal conditions.
Mounting Orientation The Arena™ Hazer 3 is a haze machine and it uses fluid. Keep this in mind when selecting the orientation, as the fluid will leak out of the fluid reservoir if the unit is not horizontal. Rigging When hanging this product overhead, always use all three of the fly points. The cables and structure to which you are hanging the product from must be capable of supporting at least 10 times the weight of the Arena™ Hazer 3.
4. OPERATION Control Panel Operation To access the control panel functions, use the four buttons located underneath the display.
Configuration (DMX Mode) Setting this product to operate in DMX mode will allow you to control it with a DMX controller. 1) Connect this product to a suitable power outlet 2) Turn this product on 3) Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket of this product. Starting Address When selecting a starting DMX address, you must always consider the number of DMX channels assigned to the selected DMX mode.
Configuration (Stand-alone Modes) Timer Mode To enable the Timer mode, do the following: 1) Connect this product to a suitable power outlet 2) Turn this product on. 3) Press repeatedly until Interval Set shows on the display. 4) Use or to select the time in between haze. 5) Press repeatedly until Duration Set shows on the display. 6) Use or to select the duration of haze. 7) Press repeatedly until Timer Out shows on the display.
5. TECHNICAL INFORMATION General Maintenance Do not allow the fog machine to become contaminated. After every 40 hours of continuous operation, it is recommended to run a cleaning solution composed of 80% distilled water and 20% distilled vinegar through the system to prevent the accumulation of particulate matter in the heating element. The recommended cleaning regimen is as follows: 1) 2) 3) 4) Empty all fog liquid from the machine. Add cleaning solution to tank. Plug unit in and allow it to warm up.
General Troubleshooting Symptom External circuit breaker or fuse keeps blowing Product does not power up Possible Cause Possible Action • Excessive load on the circuit • Make sure that the total load does not exceed 80% of the breaker or fuse nominal current • Short circuit along the power lines • Check the power lines and power cords • No energy on power outlet • • Check power outlet Change to another outlet • Loose or damaged power cord • Check the power cord • Blown fuse • Replace
Returns Procedure The user must send the merchandise prepaid, in the original box, and with its original packing and accessories. CHAUVET® will not issue call tags. Call CHAUVET® and request a Return Merchandise Authorization (RMA) number before shipping the fixture. Be prepared to provide the model number, serial number, and a brief description of the cause for the return. The user must clearly label the package with a Return Merchandise Authorization (RMA) number.
DMX Primer The USITT DMX512-A data transmission protocol (DMX, from now on) is based on the EIA-485 standard and it has 512 channels (001 to 512). This system requires a controller (DMX controller), one or more DMX compatible fixtures, and a DMX circuit (also known as “DMX universe”) to link the fixtures to the controller. Depending on their complexity and features, DMX compatible fixtures may require from one to more than 30 DMX channels to operate.
DMX Cabling The DMX protocol requires using special data cables to accommodate for the high speed digital signals it uses. Despite their apparent similarities, data cables are electrically different from standard microphone cables because they can carry high frequency digital signals and have better protection against electromagnetic interference. You can purchase CHAUVET® certified DMX cables directly from a dealer/distributor or make your own DMX cable.
6. TECHNICAL SPECIFICATIONS Dimensions and Weight Length Width Height Weight 22 in (560 mm) 11.3 in (287 mm) 11 in (280 mm) 30.5 lbs (13.8 kg) Note: Dimensions in inches rounded to the nearest decimal digit. Power Power Supply Type Range Voltage Selection Magnetic (internal) 120 V, 60 Hz or 230 V, 50 Hz None (Fixed voltage) Parameter 120 V, 60 Hz 230 V, 50 Hz Consumption 1,640 W (13.71 A) 1,640 W (6.