USER MANUAL
Edition Notes The WELL Panel User Manual includes a description, safety precautions, installation, programming, operation and maintenance instructions for the WELL Panel as of the release date of this edition. Trademarks CHAUVET, the Chauvet logo and WELL Panel are registered trademarks or trademarks of Chauvet & Sons, LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries.
Table of Contents TABLE OF CONTENTS 1. Before You Begin ....................................................................... What Is Included ........................................................................................... Claims ........................................................................................................... Manual Conventions ..................................................................................... Symbols .............................................
Table of Contents Static Mode .................................................................................................................... Red Shift ........................................................................................................................ Dimmer Profiles.............................................................................................................. White Balance ..............................................................................................
Before You Begin 1. Before You Begin What Is Included • • • WELL Panel Seetronic Powerkon IP65 power cord Color-blending filter lens • • Omega bracket with mounting hardware Quick Reference Guide Claims Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.
Before You Begin Safety Notes Read all the following safety notes before working with this product. These notes contain important information about the installation, usage, and maintenance of this product. This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained, certified technicians. Do not open the housing or attempt any repairs. All applicable local codes and regulations apply to proper installation of this product.
Introduction 2. Introduction Description The WELL Panel is a completely wireless, IP65-rated, battery-powered RGBW LED fixture that can be controlled via W-DMX, DMX, IR remote (not included), or manually from the control panel. The WELL Panel comes with color-blending filter lens for an even diffused light and Omega brackets for easy mounting. Its 170° rotation of the panel from the base allows for easy control of direction of light.
Introduction Product Overview Display Menu buttons Power button Tilt adjustment knobs DMX in Power in Power out DMX out Product Dimensions 436 mm 17.17 in 159 mm 6.26 in 338 mm 13.3 in 260 mm 10.24 in 88 mm 3.46 in 135 mm 5.31 in Page 4 of 22 WELL Panel User Manual Rev.
Setup 3. Setup AC Power Each WELL Panel has an auto-ranging battery charger inside the fixture that works with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the power requirements for the WELL Panel, refer to the label affixed to the product. You can also refer to the Technical Specifications chart in this manual. The listed current rating indicates the maximum current draw during normal operation. For more information, download Sizing Circuit Breakers from the Chauvet website: www.
Setup DMX Linking You can link the WELL Panel to a DMX controller using a wireless DMX connection. If using other DMXcompatible products with this product, you can control each individually with a single DMX controller. DMX Personalities The WELL Panel uses a wireless DMX data connection for the 4Ch, 8Ch, 12Ch, 13Ch, and 21Ch DMX personalities. • Refer to the Introduction chapter for a brief description of each DMX personality.
Setup Master/Slave Connectivity The Master/Slave mode allows an WELL Panel (the master) to control one or more WELL Panel products (the slaves) without a DMX controller. One WELL Panel becomes the master when running an auto program, or by being in Static mode. You must configure each slave’s control panel to operate in Slave mode. During Master/Slave operation, the slaves will operate in unison with the master. DO NOT connect a DMX controller to products operating in Master/Slave mode.
Operation 4. Operation Control Panel Operation Button
Operation Main Level Programming Levels R G B W GB RB RG Dimmer RGB Fixed Color 000–255 RW GW BW RGW RBW GBW Static RGBW 2800K 3200K 3500K 4000K Color Dimmer 4500K Temperature 000–255 5000K 5600K 6000K 6500K Red Green Manual 000–255 Color Mixer Blue White Auto Show Auto 1–9 001–100 On Red Shift Off Master Master/Slave Slave Off Dimmer Mode Dimmer 1–3 Linear Square Dimmer Curve I Squa Scurve Off Red White Balance Green Manual 125–255 Blue White WELL Panel User Manual Rev.
Operation Main Level Programming Levels LED Frequency 600Hz 1200Hz 2000Hz 4000Hz 6000Hz 25KHz Wireless Setting Receive On/Off Receive Reset Sets the PWM frequency On Off No Yes Stay In State Line Voltage Power Loss Mode All At Full Dim Out Off 3 Hours 5 Hours Run Time 8 Hours 12 Hours 10S 30S Back Light 2Min Always On On Off Key Lock Information Factory Reset Page 10 of 22 Fixture Hours Version UID Description <_ _ _ _H>
Operation Configuration (DMX) Use control configurations to operate the product with a DMX controller. For information on how to configure wireless DMX, see Wireless Operation. Control Personalities This setting allows you to choose a particular control personality. 1. Go to the DMX Channel main level. 2. Select the desired personality (see table below).
Operation DMX Values Zones for DMX Control 1 2 3 21Ch Channel Function 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Dimmer Fine dimmer Red 1 Green 1 Blue 1 White 1 Red 2 Green 2 Blue 2 White 2 Red 3 Green 3 Blue 3 White 3 15 Strobe 16 Color macro Page 12 of 22 Value 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 010 011 255 000 010 011 030 031 050 051 070 071 090 091 110 111 130 131 150 151 1
Operation Channel Function 17 Color temperature 18 Auto programs 19 Auto program speed 20 Dimmer speed mode 21 Red shift Value 000 005 006 025 026 050 051 075 076 100 101 125 126 150 151 175 176 200 201 225 226 255 000 010 011 037 038 064 065 091 092 118 119 145 146 172 173 199 200 226 227 255 000 255 000 051 052 101 102 152 153 203 204 255 000 010 011 127 128 255 Percent/Setting No function 2800K 3200K 3500K 4000K 4500K 5000K 5600K 60
Operation Channel Function 8 Color macro 9 Color temperature 10 Auto programs 11 Auto program speed 12 Dimmer speed mode Page 14 of 22 Value 000 010 011 030 031 050 051 070 071 090 091 110 111 130 131 150 151 170 171 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 241 245 246 250 251 255 000 005 006 025 026 050 051 075 076 100 101 125 126 150 151 175 176 200 201 225 226 255 000 010 011 037 038 064 065 09
Operation Channel Function Value Percent/Setting 13 Red shift 000 010 011 127 128 255 Channel Function Value 1 2 3 4 5 6 7 8 9 10 11 12 Red 1 Green 1 Blue 1 White 1 Red 2 Green 2 Blue 2 White 2 Red 3 Green 3 Blue 3 White 3 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 000 255 0–100% 0–100% 0–100% 0–100% 0–100% 0–100% 0–100% 0–100% 0–100% 0–100% 0–100% 0–100% Function Dimmer Dimmer fine Red Green Blue White Value 000 255
Operation Configuration (Standalone) Use standalone configuration to operate the product without a DMX controller. Auto Programs Auto programs allow for dynamic blinder effects without a DMX controller. 1. Go to the Auto Show main level. 2. Select the desired auto (Auto 1–5). 3. Select the desired speed (1–100). The auto programs cannot be edited. Static Mode The Static mode allows for permanent dimmer and strobe presets without a DMX controller. 1. Go to the Static main level. 2.
Operation Line Voltage Power Loss Mode This option sets the action that the fixture will during a line power loss. 1. Go to the Line Voltage Power Loss Mode main level. 2.
Operation Infrared Remote Control Infrared (IR) mode allows the product to be controlled with an infrared remote controller. The IR remote can remotely set the product to various modes; adjust the color, speed, and sensitivity; and set the strobe. The WELL Panel is compatible with the IR remote (sold separately) from Chauvet. It may be necessary to turn the product off and on again when switching from W-DMX to IRC and vise-versa.
Technical Information 5. Technical Information Product Maintenance To maintain optimum performance and minimize wear, clean this product frequently. Usage and environment are contributing factors in determining the cleaning frequency. Clean this product at least twice a month. Dust build-up reduces light output performance and can cause overheating. This can lead to reduced light source life and increased mechanical wear. To clean the product: 1. Unplug the product from power and switch off. 2.
Technical Specifications 6. Technical Specifications Dimensions and Weight Length 17.17 in (436 mm) Width 5.31 in (135 mm) Height 10.24 in (260 mm) Weight 22.6 lb (10.3 kg) Note: Dimensions in inches are rounded. Power Power Supply Type Switching (internal) Parameter Consumption (single) Operating Current (single) Range 100 to 240 VAC, 50/60 Hz 120 V, 60 Hz 123 W 1.029 A Power I/O Power input connector Power output connector Power cord plug Voltage Selection Auto-ranging 208 V, 60 Hz 124 W 0.
Returns Returns Send the product prepaid, in the original box, and with the original packing and accessories. Chauvet will not issue call tags. Call Chauvet and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause(s) for the return. To submit a service request online, go to www.chauvetprofessional.com/service-request. Clearly label the package with an RMA number.
Contact Us Contact Us General Information Technical Support Chauvet World Headquarters Address: 5200 NW 108th Ave. Sunrise, FL 33351 Voice: (954) 577-4455 Fax: (954) 929-5560 Toll Free: (800) 762-1084 Voice: (844) 393-7575 Fax: (954) 756-8015 Email: chauvetcs@chauvetlighting.com Website: www.chauvetprofessional.com Chauvet Europe Ltd Address: Unit 1C Brookhill Road Industrial Estate Pinxton, Nottingham, UK NG16 6NT Voice: +44 (0) 1773 511115 Fax: +44 (0) 1773 511110 Email: UKtech@chauvetlighting.