ISLAND II III CONTENTS O P E R AT I N G I N S T R U C T I O N S Fuel 4 Door Operation 4 Wood Ash Removal Grate 4 Riddling 5 Controlling The Fire 5 Ash Clearance 5 Tool Holder 5 Lighting 6 Refuelling 7 Maintenance 7 Throat Plate & Flueway Cleaning 7 Chimney Sweeping 8 Trouble Shooting 8 If you need Further help 9 INSTALLATION INSTRUCTIONS Health & Safety Precautions 10 Unpacking the Stove 10 Specification 10 CO Alarms 10 Chimney 10 Hearth & Fire Surround 11 Connection
charnwood ISLAND OPERATING INSTRUCTIONS II III Before lighting the stove check with the installer that the work and checks described in the Installation Instructions have been carried out correctly and that the chimney has been swept, is sound and free from any obstructions. The stove is not suitable for use in a shared flue system. Your Island stove has been designed to work with the minimum Maximum Length Approx. Diameter Island 2 440mm (17.25") Up to 100 mm (4") Island 3 550mm (21.
charnwood ISLAND OPERATING INSTRUCTIONS II III top of it. When in the closed position ash is able to build up on the Fig. 3 Air control grate as is necessary for effective wood burning. Movement of the grate from one position to the other is effected Air control handle using the tool supplied as shown in Fig. 2. The grate is put into the open position by moving the tool up until the handle is in the 1 o'clock position.
charnwood ISLAND OPERATING INSTRUCTIONS II III Fig. 6 Adding larger logs LIGHTING On initial lighting, the stove may smoke and give off an odour as the silicon paint with which the firebox is painted reacts to the heat. This is normal and will cease after a short time, but meanwhile the room should be kept well ventilated. At first only light a small fire and burn it slowly for two hours to allow any residual moisture in the bricks to evaporate. Fig.
charnwood ISLAND OPERATING INSTRUCTIONS II III Fig. 8. Throat Plate REFUELLING Keep the firebox filled up to the level of the air holes in the back firebrick, but do not overfill to prevent fuel from spilling over the top of the front fire bar. Logs should be evenly distributed, filling the firebed to give the most pleasing flame pattern. The air control must be fully opened after refuelling until the flames are established above the fire. It is best to refuel on to a hot bed of ash.
charnwood ISLAND OPERATING INSTRUCTIONS II III CHIMNEY SWEEPING glass to blacken. The chimney should be swept at least once a year. Where a top d) There is a bypass slide that can be adjusted to suit the particular outlet is used it will generally be possible to sweep the chimney installation. This allows a small amount of airwash air to enter the through the appliance. stove even when the air control is closed.
charnwood ISLAND OPERATING INSTRUCTIONS II III should not occur. However, if a chimney fire does occur push the air control in fully tightly close the doors of the appliance. This should cause the chimney fire to go out in which case the control should be kept closed until the stove has gone out. The chimney and flueways should then be cleaned. If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately.
charnwood ISLAND INSTALLATION INSTRUCTIONS II III HEALTH AND SAFET Y PRECAUTIONS UNPACKING THE STOVE Please take care when installing the stove that the requirements of The stove arrives bolted and shrink-wrapped to its pallet. There the Health and Safety at Work Act 1974 are met. must be adequate facilities for unloading and manoeuvring into position. The wrapping is first removed, then the stove can be Some types of fire cement are caustic and should not be allowed to released from the pallet.
charnwood ISLAND INSTALLATION INSTRUCTIONS II III If it is found that there is excessive draw in the chimney then a Fig. 9 Vertical Register Plate With Bricked Up Fireplace draught stabilizer should be fitted. Soot Door In Side or Rear Of Chimney It is important that there is sufficient draw in the chimney and that the chimney does not suffer from down-draught. When the chimney Register Plate is warm the draw should be not less than 0.05 inches water gauge (12Pa).
charnwood ISLAND INSTALLATION INSTRUCTIONS II III Fig. 12 Horizontal Register Plate With Optional Vertical Rear Flue Connector ® COMMISSIONING On completion of the installation and after allowing a suitable period Alternative Soot Door Positions of time for the fire cement and mortar to dry out, the stove should be lit and checked to ensure that smoke and fumes are taken from the appliance up the chimney and emitted safely. Also check all joints and seals.
charnwood ISLAND ISLAND II DIMENSIONS (mm) II III ® 88 143 160 132 charnwood 476 421 ISLANDII Flue outlet to suit 150mm (6") flue pipe TOP VIEW Optional Vertical Rear Flue Adapter 634 155 674 619 STANDARD LEG 504 99 87 365 605 634 Optional External Air Manifold 393 710 48 HIGH LEG 765 447 595 190 622 179 331 447 634 875 820 STORE STAND 705 295 584 FRONT VIEW 301 451 Max dim.
charnwood ISLAND ISLAND III DIMENSIONS (mm) II III 105 186 171 charnwood 147 533 452 ISLANDIII Flue outlet to suit 175mm (7") flue pipe TOP VIEW Optional Vertical Rear Flue Adapter 765 196 763 588 STANDARD LEG 713 108 107 400 484 732 765 Optional External air manifold 428 845 795 HIGH LEG 48 670 189 190 400 484 750 995 820 STORE STAND 945 339 335 309 714 FRONT VIEW Max dim.
Charnwood Island II (bze) Par ts List ® Issue A 50 60 53 16 48 58 13 63 56 51 49 12 52 62 11 9 47 6 7 5 46 29 8 57 18 34 3 61 27 26 24 4 25 30 21 14 33 23 20 19 59 45 42 32 43 35 37 36 38 39 44 41 40 17 22 28 15 31 Item Part No. Description Item Part No.
Charnwood Island III (cze) Par ts List ® Issue A 51 13 54 59 14 49 52 57 61 12 50 64 63 11 29 47 58 60 53 7 8 4 6 48 9 18 20 46 30 15 62 17 22 33 21 32 28 24 25 23 5 35 42 43 45 27 26 34 3 19 16 37 44 38 39 41 36 40 31 Item Part No. Description Item Part No.
char n w o o d A.J WELLS & SONS LTD Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered in England No. 03809371 EN13240:2001 ISLAND II III ROOMHEATERS FIRED BY SOLID FUEL Island II Island III BZE50-CPD-2015 CZE50-CPD-2015 WOOD LOGS WOOD LOGS Emission of CO in combustion products: 0.09% 0.
your premier dealer charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T: + 4 4 ( 0 ) 19 8 3 5 3 7 7 7 7 • F : + 4 4 ( 0 ) 19 8 3 5 3 7 7 8 8 • C O N TA C T U S AT W W W. C H A R N W O O D . C O M ® A D i v i s i o n o f A . J . We l l s & S o n s L i m i t e d Re g i s t e r e d i n E n g l a n d N o .