Declaration of Performance
Declaration of Performance
No.SXE2 0 0 - C P R - 15
Product-Type
Roomheaters fired by Solid Fuel
Intended use
Solid fuel burning Space heaters
Manufacturer
Charnwood A.J.Wells & Sons Ltd., Bishops Way, Newport, Isle of Wight, PO30 5WS UK
Tel +44 1983537770 www.charnwood.com
System of assessment and verification of
constancy of performance (CPR Annex V)
System 3 ISO9001:2008 Certified
Certifying Authority:- SGS United Kingdom Ltd Systems & Services Certification
Rossmore Business Park Ellesmere Port Cheshire CH65 3EN UK
t+44 (0)151 350-6666 f +44(0)151 350-6600 www.sgs.com
Notified body
Notified body No.
RRF
1625
Perfomance against Harmonised
Standards
BSEN13240:2001 + Amd 2:2004
PD6434:1969
Appliance Model
Test Report No.
Cove II
40 14 3809
Cove III
40 14 3810
Space heating thermal output
8kW
12kW
Energy efficiency
77%
80%
Mean flue gas temperature
336°C
330°C
Emission of CO in combustion products
0.10%
0.10%
3
Particles (mg/m )
n
15
17
Minimum distance to
combustible materials
Side
Rear
450mm
600mm
500mm
500mm
Declaration
The performance of these products conforms to the declared performance.
This declaration of performance is issued under the sole responsibility of the manufacturer
Signed on behalf of the manufacturer
Paul Wells
Technical Director
Newport, Isle of Wight 9th October 2013 ................................................................................
Declaration of Performance
No.SXE2 0 0 - C P R - 15
Product-Type
Roomheaters fired by Solid Fuel
Intended use
Solid fuel burning Space heaters
Manufacturer
Charnwood A.J.Wells & Sons Ltd., Bishops Way, Newport, Isle of Wight, PO30 5WS UK
Tel +44 1983537770 www.charnwood.com
System of assessment and
verification of constancy of
performance (CPR Annex V)
System 3 ISO9001:2008 Certified
Certifying Authority:- SGS United Kingdom Ltd Systems & Services Certification
Rossmore Business Park Ellesmere Port Cheshire CH65 3EN UK
t+44 (0)151 350-6666 f +44(0)151 350-6600 www.sgs.com
Notified body
Notified body No.
RRF
1625
Perfomance against
Harmonised Standards
BSEN13240:2001 + Amd 2:2004
PD6434:1969
Appliance Model
Test Report No.
Cove I
Cove II
40 14 3809
Cove III
40 14 3810
Space heating thermal output
kW
8.5kW
12.4kW
Energy efficiency
%
77%
80%
Mean flue gas temperature
°C
336°C
330°C
Emission of CO in combustion
products
%
0.10%
0.10%
3
Particles (mg/m )
n
15
17
Minimum distance to
combustible materials
Side
Rear
550mm
550mm
450mm
600mm
500mm
500mm
Declaration
The performance of these products conforms to the declared performance.
This declaration of performance is issued under the sole responsibility of the manufacturer
Signed on behalf of the manufacturer
Paul Wells
Technical Director
Newport, Isle of Wight 9th October 2013 ................................................................................