® country 4 blu Operating & Installation Instructions
CONTENTS QUICK GUIDE 4 OPERATING INSTRUCTIONS 5 FUEL 5 LIGHTING 5 CONTROLLING THE FIRE 5 REFUELLING 6 ASH CLEARANCE 6 REDUCED BURNING 6 MAINTENANCE 6 THROAT PLATE AND FLUEWAY CLEANING 7 CHIMNEY SWEEPING 7 TROUBLE SHOOTING 8 CO ALARM 8 IF YOU NEED FURTHER HELP 8 UNPACKING THE STOVE 9 HEALTH AND SAFETY PRECAUTIONS 9 CO ALARMS 9 SPECIFICATION 9 CHIMNEY 9 INSTALLATION INSTRUCTIONS 9 HEARTH AND FIRE SURROUND 10 CONNECTIONS TO FLUES 10 SOOT DOORS 11 PRE LIGHTING CHECK
QUICK GUIDE ® Throat plate Improves efficiency of stove by slowing down flue gases Door Keep closed when stove is in use Door handle Pull to open Fuel retainer Ensure fuel does not protrude beyond retainer MAINTENANCE AND CLEANING GLASS Wipe with damp, lint free cloth. Any stubborn deposits on the glass may be removed with a proprietary stove glass cleaner or ceramic hob cleaner. THROAT PLATE & UPPER BAFFLE Take down once a month and clean.
OPERATING INSTRUCTIONS Congratulations on becoming the owner of a Charnwood Country ® Approximate suitable log sizes are: 4 Blu Stove. Your stove has been approved in smoke control areas 225mm(10in) long and 75mm (3in) diameter to burn wood logs if it is used in accordance with these instructions. It is very important that you read and understand these instructions Log moisture content of less than 20% is recommended. before using the stove.
OPERATING INSTRUCTIONS ® The airwash control is used most of the time to control the burning not project over the fuel retainer or damage to the glass may be rate and to keep the glass clean. Fully extended gives full airwash for caused when the door is closed. It can also cause the glass to blacken faster burning and clean glass whereas fully closed gives low burning. up.
OPERATING INSTRUCTIONS When Not in Use ® The upper baffle plate rests centrally on top of the air wash tubes. The stud on the baffle plate should be located into the hole on the If the fire is going to be out of use for a long period (for instance in bracket the summer) then to prevent condensation, and hence corrosion, the air control should be left fully open and the fire door left ajar. It Is also Fig.2 Throat Plate Location advisable to sweep the chimney and clean out the fire.
OPERATING INSTRUCTIONS TROUBLE SHOOTING ® not emit fumes. Occasional fumes from de-ashing and re-fuelling may occur. Persistent fume emission is potentially dangerous and must not be tolerated. If fume emission does persist, then the Fire Will Not Burn following immediate actions should be taken: Check that: a) Open doors and windows to ventilate the room and then leave a) the air inlet is not obstructed in any way, the premises.
INSTALLATION INSTRUCTIONS ® UNPACKING THE STOVE BSEN 15287-1:2007 must be fulfilled. Local Authority Bylaws The stove arrives fixed its pallet facing up. There must be adequate European Standards, regarding the installation of Solid Fuel burning facilities for unloading and manoeuvring into position The wrapping appliances, flues and chimneys must also be observed.
INSTALLATION INSTRUCTIONS ® should not have an excessive cross sectional area. If it was previously it should be a minimum of 460mm (18”), and preferably 600mm used by an open fire then the chimney should be swept one month (24”) from the appliance. In some situations it may be necessary to after installation to clear any soot falls which may have occurred due shield the beam or mantelpiece to protect it. to the difference in combustion between the stove and the open fire.
INSTALLATION INSTRUCTIONS removed, have the webbing fitted to its sealing face, and fitted to ® Fig. 7 Horizontal Register Plate With Top Flue Connection the rear flue outlet. Ensure that the fold on the clamping plate is Alternative soot door positions in line with the lugs on the firebox as shown in Fig 9. Ensure that the clamping plate does not prevent the throat plate from seating correctly. All flue connections must be well sealed.
INSTALLATION INSTRUCTIONS operating instructions with the customer and advise them on the use ® Fig. 9. Flue Blanking Plate. of the appliance. Blanking Plate CAA AND SMOKE CONTROL Back of Stove Inside of Stove Clamping Plate The Clean Air Act 1993 and Smoke Control Areas M8 Nut Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area.
DIMENSIONS ® 128 326 To suit 125mm (5”) flue pipe PLAN VIEW 416 600 545 437 386 FRONT 250 SIDE REAR 92 173 291 WITH HEATSHIELD WITH VERTICAL REAR FLUE ADAPTOR 13
PARTSCountry LIST4 BLU Parts List Charnwood ® Issue A 28 27 7 8 23 11 25 26 20 19 10 18 10 12 11 9 13 9 29 14 24 22 17 15 6 5 4 21 16 16 16 Item Part No. 1* 2* 3* 4 5 6 7 8 9 10 11 12 13 14 15 008/PV21 008/FW29 008/PV55 006/PV19 004/KV23 002/EY23 010/EYE032 011/EYE031 010/EYE029 010/EYE028 010/EYE016 012/EYE011 008/ST068/2 008/FW28 002/PV03 Description Door Seal Door Seal Adhesive Glass Seal Kit Glass (Inc Seal) Glass Retainer Fuel Retainer Upper Baffle Throat Plate Brick L.H.
CERTIFIC ATION ® AJ WELLS & SONS LTD Bishops Way, Newport, Isle Of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered In England No. 03809371 CE certificate for compliance with EN13240:2001 EN13240:2001 ROOMHEATERS FIRED BY SOLID FUEL Model: COUNTRY 4 BLU EC Certificate of conformity no: EYE11-CPD-2018 WOOD LOGS Fuel type: Rated space heating thermal output: 5kW Emission of CO in combustion products: 0.
MODÈLE MODELLO MODEL CLASSE D’EFFICACITÉ CLASSE DI EFFICIENZA KLASA EFEKTYWNOŚCI PUISSANCE THERMIQUE NOMINALE INDICE DI EFFICIENZA ENERGETICA EFFICACITÉ ÉNERGÉTIQUE SAISONNIÈRE POUR LE CHAUFFAGE DES LOCAUX EFFICIENZA ENERGETICA STAGIONALE DI RISCALDAMENTO DI AMBIENTE AIRE 3 AIRE 5 AIRE 7 ARC 5 ARC 7 BAY 5 BAY 5 BX BAY 5 VL BEMBRIDGE C-FOUR BLU C-FOUR INSERT C-FIVE BLU C-SIX C-SIX BLU C-EIGHT BLU COUNTRY 4 BLU COUNTRY 6 COVE 3 BLU ISLAND I (AP) ISLAND II (BP) SKYE 5 SKYE 7 C-FOUR C-FIVE C-SEVEN C-SE
your premier dealer