® charnwood C-SERIES Operating & Installation Instructions
CONTENTS O P E R AT I N G I N S T R U C T I O N S Fuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Fitting The Wood Ash Removal Grate . . . . . 4 Lighting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Controlling The Fire . . . . . . . . . . . . . . . . . . . 5 Refuelling . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Ash Clearance . . . . . . . . . . . . . . . . . . . . . . . 5 Reduced Burning . . . . . . . . . . . . . . . . . . . . . 6 Maintenance . . . . . . .
OPERATING INSTRUCTIONS ® Congratulations on becoming the owner of a Charnwood C-Series FITTING THE WOOD ASH REMOVAL Stove. GRATE Before lighting the stove check with the installer that the work and Tools Required: checks described in the Installation Instructions have been carried out 10mm Socket correctly and that the chimney has been swept, is sound and free Pozidriv screwdriver from any obstructions. The stove is not suitable for use in a shared Before fitting the wood ash removal grate (Fig.
OPERATING INSTRUCTIONS ® LIGHTING CONTROLLING THE FIRE On initial lighting, the stove may smoke and give off an odour as the The rate of burning and hence the output is controlled by the air silicon paint with which the firebox is painted reacts to the heat. This control (see Fig. 2). is normal and will cease after a short time, but meanwhile the room Open the air control fully (boost position) when lighting or when should be kept well ventilated. rapid burning is required.
OPERATING INSTRUCTIONS ® REDUCED BURNING Door Seals For the fire to operate correctly it is important that the door seals For reduced burning the fire door must be closed. are in good condition. Check that they do not become worn or When burning wood in areas that are not smoke controlled, load frayed and replace them when necessary.
OPERATING INSTRUCTIONS ® a) Wet or unseasoned wood, or logs overhanging the front fence will CHIMNEY SWEEPING cause the glass to blacken. Where the chimney previously served an open fire, it is possible that b) The airwash relies on a supply of heated air to keep the glass clean, the higher flue gas temperature from a stove may loosen soot therefore, when lighting the stove allow the firebed to become well deposits with the consequent risk of flue blockage.
OPERATING INSTRUCTIONS ® d) Door seals and airwash slide are intact. Chimney Fires If the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does occur close the air control, and tightly close the door of the appliance. This should cause the chimney fire to go out in which case the controls should be kept closed until the stove has gone out. The chimney and flueways should then be cleaned.
INSTALLATION INSTRUCTIONS ® HEALTH AND SAFET Y PRECAUTIONS The wrapping is first removed, then the stove released from the pallet by either removing the single bolt (C-4) or 4 pallet bolts(C-5 to Please take care when installing the stove that the requirements of C-8) using a 10mm spanner. The pallet brackets can now be removed the Health and Safety at Work Act 1974 are met.
INSTALLATION INSTRUCTIONS ® Fig. 4. Vertical Register Plate With Bricked Up Fireplace CHIMNEY Soot Door In Side or Rear Of Chimney In order for the appliance to perform satisfactorily the chimney height must not be less than 4 metres measured vertically from the outlet of the stove to the top of the chimney.
INSTALLATION INSTRUCTIONS ® Fig. 7. Horizontal Register Plate With Optional Vertical Rear Flue Connector Fig. 8. Flue Blanking Plate. Back of Stove Blanking Plate Inside back of Stove Alternative Soot Door Positions Clamping Plate M8 Nut Glass Fibre Webbing Blanking Plate Register Plate With Soot Door Clamping plate finishes flush with inside face of firebox top and bottom. Seal Blanking Plate with Glass Fibre Webbing This may be stainless steel, cast iron, or thick wall steel pipe.
INSTALLATION INSTRUCTIONS ® PRE LIGHTING CHECK Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas Ensure that the throat plate is fitted in the roof of the appliance. The and you can contact them for details of Clean Air Act requirements. location and positioning of the throat plate is shown in Fig. 3.
18 A.J WELLS & SONS LTD Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered in England No. 03809371 CE Certificate for compliance with EN13240:2001 EN13240:2001 C SERIES ROOMHEATERS FIRED BY SOLID FUEL C Four* C Five C Six C Seven C Eight BRE44-CPD-2015 NRE44-CPD-2015 CRE44-CPD-2015 ERE44-CPD-2015 DRE44-CPD-2015 WOOD LOGS WOOD LOGS WOOD LOGS WOOD LOGS WOOD LOGS Emission of CO in combustion products: 0.08% 0.06% 0.07% 0.07% 0.
C-FOUR DIMENSIONS (mm) ® 82 114 154 131 405 373 Plan View 140 i/d to suit 125mm (5") flue pipe Optional Vertical Rear Flue Adapter Standard Model 416 144 613 560 458 84 45 267 386 64 OD 61 ID Store Stand 416 763 710 608 195 150 386 262 416 818 765 High Leg 663 247 205 386 Front 267 Side 14 Rear
C-FIVE DIMENSIONS (mm) ® 82 114 153 130 430 398 Plan View 140 i/d to suit 125mm (5") flue pipe Optional Vertical Rear Flue Adapter Standard Model 485 144 611 560 458 65 292 455 76 79 Store Stand 485 796 745 643 250 185 292 455 485 816 765 High Leg 663 271 205 292 Front Side 15 Rear
C-SIX DIMENSIONS (mm) ® 88 131 169 146 441 398 Plan View Optional Vertical Rear Flue Adapter 156 i/d to suit 150mm (6") flue pipe Standard Model 441 670 161 615 505 119 411 63 292 79 Store Stand 441 855 690 800 185 411 292 441 875 820 High Leg 710 264 205 411 292 Front Side 16 Rear
C-SEVEN DIMENSIONS (mm) ® 85 130 169 146 440 398 Plan View Optional Vertical Rear Flue Adapter 156 i/d to suit 150mm (6") flue pipe Standard Model 564 160 670 615 505 292 534 59 76 79 OD Store Stand 564 855 800 690 244 185 292 529 875 820 High Leg 710 268 205 292 Front Side 17 Rear
C-EIGHT DIMENSIONS (mm) ® 88 133 169 146 398 443 Plan View Standard Model 500 156 i/d to suit 150mm (6") flue pipe Optional Vertical Rear Flue Adapter 163 710 764 605 61 292 465 79 76 Store Stand 500 949 895 790 246 185 292 470 500 969 915 High Leg 810 268 205 292 Front Side 18 Rear
C-FOUR PARTS LIST ® Issue B 7 6 Optional Wood Ash Removal Kit 21 62 18 47 65 52 19 8 11 63 55 54 59 60 57 10 9 8 64 53 56 58 51 13 12 50 15 48 24 3 49 17 14 22 28 41 16 23 35 25 40 39 37 44 36 5 These items are only used on models prior to serial no. 100417 26 27 29 30 43 33 42 38 31 34 46 32 45 Item Part No. Description Item Part No.
C-FIVE PARTS LIST ® Issue D Optional Wood Ash Removal Kit 22 20 65 7 57 8 9 21 56 11 10 59 60 11 62 54 47 58 63 64 55 11 53 13 14 15 16 51 17 50 48 52 12 49 41 25 35 28 18 6 39 4 40 26 These items are only used on models prior to serial no. 100623 excluding serial no. 100301 100305 24 23 27 44 43 37 36 33 42 29 30 31 32 34 46 45 38 Item Part No. Description Item Part No.
C-SIX PARTS LIST ® Issue C 61 60 62 These items are only used on models prior to serial no. 100151 26a 27a Item Part No. Description Item Part No.
C-SEVEN PARTS LIST ® Issue C Optional Wood Ash Removal Kit 49 20 61 62 54 57 6 9 19 55 56 51 44 18 53 10 7 52 47 8 11 50 59 13 48 22 46 5 45 21 14 15 3 12 38 37 23 36 30 32 40 These items are only used on models prior to serial no. 100224 27 16 35 60 33 25 26a 34 27a 28 41 24 29 39 43 31 42 Item Part No. Description Item Part No.
C-EIGHT PARTS LIST ® Issue B Optional Wood Ash Removal Kit 6 62 61 44 20 7 11 19 8 8 49 54 57 56 17 51 8 13 59 52 55 8 10 53 9 14 50 47 48 45 22 5 12 46 21 3 15 16 These items are only used on models prior to serial no. 100117 38 23 36 37 22 40 35 60 26a 27a 24 41 27 39 34 32 30 43 31 25 42 28 29 33 Item Part No. Description Item Part No.
your premier dealer charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T: + 4 4 ( 0 ) 19 8 3 5 3 7 7 7 7 • F : + 4 4 ( 0 ) 19 8 3 5 3 7 7 8 8 • C O N TA C T U S AT W W W. C H A R N W O O D . C O M ® A D i v i s i o n o f A . J . We l l s & S o n s L i m i t e d Re g i s t e r e d i n E n g l a n d N o .