® Operating & Installation Instructions
CONTENTS O P E R AT I N G I N S T R U C T I O N S Fuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Fitting The Wood Ash Removal Grate . . . . . 5 Riddling . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Lighting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Controlling The Fire . . . . . . . . . . . . . . . . . . . 6 Refuelling . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Ash Clearance . . . . . . . . . . . . . . . . . . . . . . . 7 Reduced Burning . .
OPERATING Your Charnwood Bembridge at a glance QUICK GUIDEINSTRUCTIONS ® a Throat plate b Improves efficiency of stove by slowing down flue gases b Door Keep closed when stove is in use a c c Door handle Open with the supplied tool d d Fuel retainer Ensure fuel does not protrude beyond retainer Door Operation Tool LIGHTING AND CONTROLLING THE FIRE p5 Boost High Low Output Output Air control Add kindling and paper or firelighters.
OPERATING INSTRUCTIONS ® Congratulations on becoming the owner of a Charnwood Bembridge OPTIONAL WOOD ASH REMOVAL GRATE Stove. Your stove has been approved in smoke control areas to burn Wood can be burnt on the base. There is an optional wood ash wood logs if it is used in accordance with these instructions. It is very removal grate available for ash clearance only. important that you read and understand these instructions before using the stove.
OPERATING INSTRUCTIONS ® Light the stove using dry kindling wood and paper or fire lighters. Put RIDDLING the paper, or fire lighters, and kindling in the firebox and cover with a Ash should be allowed to build up and only riddled when the ash bed few small dry logs. Open the air control fully (see Fig. 3). Light the begins to be too deep. The fire should be riddled with the door shut paper or fire lighters. The door may be left cracked open for a few (see Fig. 2).
OPERATING INSTRUCTIONS ® ‘click position’ or for low burning to the fully closed position. be emptied regularly before it becomes too full. Never allow the ash When the fire is burning normally the air control gives enough to accumulate in the ashpan so that it comes in contact with the airwash to keep the glass clean. However, it will not always be underside of the grate as this will seriously damage the grate bars. possible to keep the glass clean with the air control fully closed.
OPERATING INSTRUCTIONS ® When Not in Use deposits should then be swept from the plate and into the fire. If the fire is going to be out of use for a long period (for instance in Return the throat plate to its correct position- At an angle, insert the the summer) then to prevent condensation, and hence corrosion, the throat plate so that it sits on top of either the right or left side brick. air control should be left fully open and the fire door left ajar.
OPERATING INSTRUCTIONS ® Blackening of Door Glass blockage. For your own safety these must be kept clean. Differences in chimney draughts mean that the best settings of the air Fire blazing out of control controls will vary for different installations. A certain amount of Check that: experimentation may be required, however the following points should be noted and with a little care should enable the glass to be a) The door is tightly closed.
INSTALLATION INSTRUCTIONS ® use in a shared flue system. UNPACKING THE STOVE In addition to these instructions the requirements of BS.8303 and The stove arrives bolted and strapped to its pallet. There must be BSEN 15287-1:2007 must be fulfilled.
INSTALLATION INSTRUCTIONS ® should not have an excessive cross sectional area. If it was previously the beam or mantelpiece to protect it. used by an open fire then the chimney should be swept one month In order for the fire to operate correctly and to allow for access, after installation to clear any soot falls which may have occurred due there must be an air gap behind the appliance of at least 75mm, but to the difference in combustion between the stove and the open fire.
INSTALLATION INSTRUCTIONS ® Fig. 9. Horizontal Register Plate With Optional Vertical Rear Flue Connector vertical rear flue connector does allow the chimney to be swept through the stove. Soot doors may either be in the actual brickwork of the chimney or in the register plate. Various positions of soot doors Alternative Soot Door Positions are shown in Figs. 6 to 9. PRE LIGHTING CHECK Register Plate With Soot Door Ensure that the throat plate is fitted in the roof of the appliance.
INSTALLATION INSTRUCTIONS ® offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a designated smoke control area. It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area unless it is used in an "exempt" appliance ("exempted" from the controls which generally apply in the smoke control area).
A.J WELLS & SONS LTD Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered in England No. 03809371 CE Certificate for compliance with EN13240:2001 EN13240:2001 ROOMHEATERS FIRED BY SOLID FUEL BEMBRIDGE EC Certificate of conformity no: AT044-CPD-2015 WOOD LOGS Fuel type: Emission of CO in combustion products: 0.06% Mean flue gas temperature: 247°C Space heating thermal output: 5.
CHARNWOOD BEMBRIDGE DIMENSIONS (mm) ® 82 114 153 130 430 398 140 i/d to suit 125mm (5") flue pipe Optional Vertical Rear Flue Adapter Plan View Standard Model 485 611 144 560 458 0 520 62 292 455 76 79 485 0 796 745 Store Stand 643 250 185 292 Front Side High Legs 455 Rear
CHARNWOOD BEMBRIDGE PARTS LIST ® Issue B 57 61 Optional Wood Ash Removal Kit 20 10 6 18 9 10 19 10 54 53 55 56 8 46 7 10 12 14 13 52 60 50 51 25 47 5 3 49 27 22 28 29 30 48 31 11 15 39 22 16 23 33 26 42 38 41 37 21 36 35 32 24 34 40 59 45 43 44 Item Part No. Description Item Part No.
your premier dealer charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T: + 4 4 ( 0 ) 19 8 3 5 3 7 7 7 7 • F : + 4 4 ( 0 ) 19 8 3 5 3 7 7 8 8 • C O N TA C T U S AT W W W. C H A R N W O O D . C O M ® A D i v i s i o n o f A . J . We l l s & S o n s L i m i t e d Re g i s t e r e d i n E n g l a n d N o .