User Instructions
A Division of A.J.Wells & Sons Limited Registered in England No. 03809371
15
Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom
A.J WELLS & SONS LTDA.J WELLS & SONS LTD
EN13229:2001/A2:2004/AC:2007
INSET APPLIANCES INCLUDING OPEN FIRES
FIRED BY SOLID FUELS
Model
Bay 5GT
Bay 5
Bay 5VL
EC Certificate of conformity no:
MR-CPD-2015
XR-CPD-2015
BT-CPD-2015
Fuel type:
WOOD LOGS
WOOD LOGS
WOOD LOGS
Emission of CO in combustion
products:
0.08%
0.10%
0.10%
Mean flue gas temperature:
286°C
279°C
279°C
Space heating thermal output:
5.8kW
5.0kW
5.0kW
Energy efficiency
80%
81%
81%
Minimum distance to
combustible materials:
Casing Side:
Casing Rear:
Room, side:
Room, above:
Room, in front of glass
100mm + 100mm insulation
100mm + 100mm insulation
150mm
460mm
1000mm
100mm + 80mm insulation
100mm + 80mm insulation
190mm
350mm
900mm
100mm + 80mm insulation
100mm + 80mm insulation
190mm
350mm
900mm