® Operating & Installation Instructions
CONTENTS O P E R AT I N G I N S T R U C T I O N S Fuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Multi Grate . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Riddling . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Lighting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Controlling The Fire . . . . . . . . . . . . . . . . . . . 6 Refuelling . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Ash Clearance . . . . . . . . . . . . . . . . . . . . . . .
OPERATING Your Charnwood at a glance QUICK GUIDEINSTRUCTIONS ® Operation Tool a Throat plate Improves efficiency of stove by slowing down flue gases b Door Keep closed when stove is in use a c Door handle e Pull to open d b d Riddler knob Use operating tool to riddle c e Fuel retainer Ensure fuel does not protrude beyond retainer Air control MAINTENANCE AND CLEANING p6 Boost High Output Low Output Glass Wipe with damp, lint free cloth.
OPERATING INSTRUCTIONS ® Congratulations on becoming the owner of a Charnwood Arc Stove. Wood logs Your stove has been approved in smoke control areas to burn wood Only dry well seasoned wood should be burnt on this appliance as logs if it is used in accordance with these instructions. It is very burning wet unseasoned wood will give rise to heavy tar deposits in important that you read and understand these instructions before the stove, on the glass and within the chimney.
OPERATING INSTRUCTIONS ® Fig.1 Operating the multi grate quickly. When the kindling wood is well alight add a few more small logs, close the door but leave the air control fully open. When the flames are established around these logs, load the stove with the required fuel load. Maintain the air control at maximum at this stage. Solid Fuel Once the fire is up to temperature the airwash system will begin to work, so allow the fire to become hot before adjusting the air control to the required setting.
OPERATING INSTRUCTIONS ® contact with the underside of the grate as this will seriously damage REFUELLING the grate bars. Keep the firebox well filled but do not allow fuel to spill over the top To make ash removal easier there are ash carriers available. These of the fuel retainer. may be purchased from your supplier or, in case of difficulty, from Logs should be evenly distributed, filling the firebed to give the most Charnwood. pleasing flame pattern.
OPERATING INSTRUCTIONS ® deposits on the glass may be removed with a proprietary stove glass tubes. To return the lower throat plate to its correct position- At an cleaner or ceramic hob cleaner. Do not use abrasive cleaners or pads angle, insert the throat plate so that it sits on top of either the right as these can scratch the surface which will weaken the glass and cause or left side brick.
OPERATING INSTRUCTIONS ® TROUBLE SHOOTING tolerated. If fume emission does persist, then the following immediate actions should be taken: Fire Will Not Burn a) Open doors and windows to ventilate the room and then leave Check that: the premises. a) the air inlet is not obstructed in any way, b) chimneys and flueways are clear, b) Let the fire out and safely dispose of the fuel from the c) a suitable fuel is being used, appliance.
INSTALLATION INSTRUCTIONS ® In addition to these instructions the requirements of BS.8303 and UNPACKING THE STOVE BSEN 15287-1:2007 must be fulfilled. Local Authority Bylaws and The stove arrives bolted and strapped to its pallet.
INSTALLATION INSTRUCTIONS ® CHIMNEY the flat front of the stove by 436mm - Arc 5, 450mm - Arc 7. In order for the appliance to perform satisfactorily the chimney height If in doubt as to the positioning of the stove, expert advice should be must not be less than 4 metres measured vertically from the outlet of sought either from the supplier or the local building inspector. The the stove to the top of the chimney.
INSTALLATION INSTRUCTIONS ® CONNECTIONS TO FLUES Fig. 9. Horizontal register plate with top flue connection Alternative Soot Door Positions The stove must be connected to the flue using flue pipe of 125mm (5") diameter - Arc 5, 150mm (6") diameter - Arc 7. This may be stainless steel, cast iron, or thick wall steel pipe. Straight lengths of Charnwood Pipe to match the stove are available if Register Plate With Soot Door required. There are several ways of connecting the stove to the flue.
INSTALLATION INSTRUCTIONS ® SOOT DOORS CAA AND SMOKE CONTROL It is possible to pass a 16 inch diameter sweeps brush through the The Clean Air Act 1993 and Smoke Control Areas appliance but in most back outlet installations it will be necessary to Under the Clean Air Act local authorities may declare the whole or have a soot door to enable the chimney to be swept. The optional part of the district of the authority to be a smoke control area.
A.J WELLS & SONS LTD 17 Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered in England No.
CHARNWOOD ARC 5 DIMENSIONS (mm) ® 163 458 Optional vertical rear flue adaptor 133 i/d to suit 125mm (5") flue pipe 783 733 Low Stand Model 983 933 Store Stand Model 15
CHARNWOOD ARC 7 DIMENSIONS (mm) ® 156 i/d to suit 150mm (6") flue pipe 169 138 516 455 Optional vertical rear flue adaptor 502 159 832 815 686 98 493 79 449 Low Stand Model 502 159 1023 1040 894 311 493 449 Store Stand Model 16 79
CHARNWOOD ARC 5 STORE STAND PARTS LIST ® Issue A 7 74 72 6 10 26 24 25 65 27 10 5 5 73 5 28 9 70 63 8 13 14 12 5 15 20 16 71 11 19 64 66 63 75 15 67 21 3 19 18 22 68 4 46 32 33 36 34 35 69 38 47 37 49 48 40 50 54 41 51 53 30 31 30 29 2 38 52 62 39 59 56 45 43 42 44 61 60 59 58 55 57 Item Part No. Description Item Part No.
CHARNWOOD ARC 5 LOW PARTS LIST ® Issue A Item Part No. Description Item Part No.
CHARNWOOD ARC 7 PARTS LIST ® Issue B 24 69 5 7 22 23 6 28 10 61 13 18 25 59 5 26 14 9 8 19 12 27 68 65 5 15 58 11 17 66 20 60 21 16 67 64 31 56 3 29 2 4 2a 36 30 63 55 71 57 34 37 62 38 72 53 70 52 49 73 39 54 46 51 50 43 48 41 44 45 47 42 40 35 33 32 ItemNo Partno Description ItemNo Partno Description 1* 2 2a 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32# 33 34 35 36 008/FW29 006/KZ018 008/KZ024 0
CHARNWOOD ARC 7 LOW PARTS LIST ® Issue B 24 66 7 22 6 23 61 13 14 18 12 11 19 25 26 28 27 65 59 63 5 9 8 58 60 15 55 57 16 17 20 64 10 5 3 29 4 56 21 62 2 2a 36 30 31 32 37 38 39 43 42 46 41 45 44 53 40 54 47 51 50 52 49 35 34 33 48 Item Part No. Description Item Part No.
your premier dealer charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T: + 4 4 ( 0 ) 19 8 3 5 3 7 7 7 7 • F : + 4 4 ( 0 ) 19 8 3 5 3 7 7 8 8 • C O N TA C T U S AT W W W. C H A R N W O O D . C O M ® A D i v i s i o n o f A . J . We l l s & S o n s L i m i t e d Re g i s t e r e d i n E n g l a n d N o .