Specifications

Photometrics:
One-Light Close-To-Ceiling
Ceiling ctc mounted • Damp location listed
ELECTRICAL DATA
Input Voltage  V
Input Frequency  Hz
Input Current . A
Input Power 
Power Factor Greater than .
THD <%
FCC Meets FCC Title , Part  Class B
Operating Temperature - °C to  °C
Dimming Yes*
*See Dimming Notes for more information
701 Millennium Blvd
Greenville, SC 29607
www.hubbelllighting.com
THIS REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION,
APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.
REPORT NUMBER: 17.03021 PAGE: 4 OF 9
ISSUE DATE: 12/01/17
PREPARED FOR: PROGRESS
CATALOG NUMBER: P350113-108-30
DEG CANDELA LUMENS
0 375
5 372 35
15 353 99
25 314 145
35 263 164
45 202 156
55 142 127
65 90 90
75 50 53
85 19 22
90 9
95 3 4
105 3 3
115 3 3
125 2 2
135 1 1
145 1 1
155 0 0
165 0 0
175 0 0
180 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0- 30 279 30.9
0- 40 444 49.0
0- 60 727 80.3
0- 90 891 98.4
90-120 10 1.1
90-130 12 1.4
90-150 14 1.6
90-180 14 1.6
0-180 905 100.0
EFFICACY = 51.4 lm/W
CIE TYPE - DIRECT
SPACING CRITERION: 1.16
130
260
390
15˚ 30˚
45˚
60˚
75˚
90˚
LEGEND
0-deg
P-K
LED Light Engine:  K  CRI CRI
System Wattage: 
Fixture delivered lumens: .
Fixture Efficacy: .
Spacing Criteria: .
CANDELA DISTRIBUTION
DEG CANDELA LUMENS

 
  
  
  
  
  
  
  
  
 
  
  
  







THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
REPORT NUMBER: 15.00371 PAGE: 2 OF 8
ISSUE DATE: 03/04/15
PREPARED FOR: PROGRESS
CATALOG NUMBER: P2301-xx30K9
LUMINAIRE: CTC Downlight Fixture with Frosted Globe- 93047261-4130
Module
LAMP CAT. NO.: 93047261-4130 Module
LAMP: 40- NICHIA 3000K LEDs
MOUNTING: CEILING
NOTE: DATA SHOWN IS ABSOLUTE FOR THE
SAMPLE PROVIDED.
DEG CANDELA LUMENS
0 301
5 301 29
15 293 83
25 277 127
35 249 156
45 211 163
55 166 149
65 119 118
75 78 83
85 47 52
90 36
95 28 31
105 17 18
115 10 10
125 0 1
135 0 0
145 0 0
155 0 0
165 0 0
175 0 0
180 0
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0-
30 239 23.4
0- 40 394 38.7
0- 60 706 69.3
0- 90 959 94.1
90-120 59 5.8
90-130 60 5.9
90-150 60 5.9
90-180 60 5.9
0-180 1019 100.0
TOTAL INPUT WATTS = 16.4
EFFICACY = 62.1 Lm/W
CIE TYPE - DIRECT
LUMINAIRE SPACING CRITERION = 1.3
110
220
330
15˚ 30˚
45˚
60˚
75˚
90˚
LED Light Engine:  K  CRI
System Wattage: 
Fixture delivered lumens: .
Fixture Efficacy: .
Spacing Criteria: .
ZONAL LUMEN SUMMARY
ZONE LUMENS %FIXT
0-30 239 23.4
0-40 394 38.7
0-60 706 69.3
0-90 959 94.1
90-120 59 5.8
90-130 60 5.9
90-150 60 5.9
90-180 60 5.9
0-180 1019 100.0
CANDELA DISTRIBUTION
DEG CANDELA LUMENS

 
  
  
  
  
  
  
  
  
 
  
  
  







Test . Test Date //