Use and Care Guide

19
DIMENSIONS AND TOLERANCES (IN INCHES) OF SPIGOTS
AND BARRELS FOR HUBLESS PIPE AND FITTINGS
Inside Outside Outside Width Thickness Gasket
Barrel Diameter Diameter Spigot of Positioning
Diameter Barrel Spigot Bead Barrel Lug
Size N
B J M (± .13) T-Nom. T-Min. W
1
1
2
1.50 ± .09 1.90 ± .06 1.96 ± .06 .25 .16 .13 1.13
2 1.96 ± .09 2.35 ± .09 2.41 ± .09 .25 .16 .13 1.13
3 2.96 ± .09 3.35 ± .09 3.41 ± .09 .25 .16 .13 1.13
4 3.94 ± .09 4.38 + .09 4.44 ± .09 .31 .19 .15 1.13
– .05
5 4.94 ± .09 5.30 + .09 5.36 ± .09 .31 .19 .15 1.50
– .05
6 5.94 ± .09 6.30 + .09 6.36 ± .09 .31 .19 .15 1.50
– .05
8 7.94 ± .13 8.38 ± .09 8.44 ± .09 .31 .23 .17 2.00
10 10.00 ± .13 10.56 ± .09 10.62 ± .09 .31 .28 .22 2.00
12 11.94 ± .09 12.50 ± .13 12.62 ± .13 .31 .28 .22 2.75
15 15.11 ± .09 15.83 ± .13 16.12 ± .13 .31 .36 .30 2.75
Hubless Cast Iron
GENERAL INFORMATION
NEVER test with or transport/store
compressed air or gas in Cast Iron pipe
or fittings.
NEVER test Cast Iron pipe or fittings
with compressed air or gas.
ONLY use Cast Iron pipe and fittings
for drain, waste and vent or sanitary
sewer applications.
Testing with or use of compressed air or gas in Cast Iron
pipe or fittings can result in explosive failures and cause
severe injury or death.
Cast Iron pipe and fittings are only intended for DWV
(drain, waste and vent) non-pressure applications. Using
cast iron pipe and fittings in pressure applications could
result in explosive failures, causing serious injury or death
or property damage.