How to Guide
115
Unstable Soil
Burial of pipe under slab in soils that are unstable is often 
accomplished by suspending the piping systems from struc-
tural slabs. The use of plastic pipe in such installations must 
CFJOBDDPSEBODFXJUI"45.'$FMMVMBSDPSFQJQFJT
specifically not permitted for these applications.
Using Plastics in Multi-Story Construc-
tion
Incorporating plastic piping systems into multi-story con-
struction raises special design considerations. Charlotte Pipe 
QMBTUJDQJQFBOEmUUJOHTBSFXBSSBOUFEUPDPOGPSNUP"45.
or other applicable product-based standard, not for any par-
ticular system design. 
Products and materials selected for use in multi-story con-
struction (four floors and up) must conform to all applicable 
CVJMEJOH QMVNCJOH BOE mSF DPEFT  1SPEVDU TFMFDUJPO BOE
or specification should be made by an architect, engineer, 
contractor, or other licensed professional. This must include 
specification of a code-compliant, chemically compatible 
firestop system with an appropriate service life, which must 
be properly installed and inspected for conformance to build-
ing, plumbing and fire codes by the responsible governmental 
authority. 
In selecting products and material for multi-story construc-
UJPODPOTJEFSBUJPOTIPVMECFHJWFOUP$IBSMPUUF1JQFTDBTU
iron soil pipe products, which are an excellent choice for 
many multi-story applications. Charlotte Pipe recommends 
SPECIAL CONSIDERATIONS
Combustion Gas Venting
Failure to properly vent combustion gas may result in 
serious injury or death from carbon monoxide.
 7bmWoi_dijWbb %ki[ f_f[ eh \_jj_d]i Wi if[Y_\_[Z Xo j^[
appliance manufacturer's installation instructions to 
vent appliances.
*UTJNQPSUBOUUPOPUFUIBUUIFDIFNJDBMQSPQFSUJFTPGBMMQMBT-
tic pipe, including CPVC pipe, change over time. Visually, 
this means that the pipe may experience color variations. The 
temperature of the water running through the pipe often de-
termines the degree of variation, with hot water causing a 
more noticeable change. Such color variations, however, do 
not indicate that the performance of the pipe has been com-
promised. The pressure bearing capabilities of CPVC pipe, in 
fact, actually increase as the pipe ages to help ensure a reli-
able, long-term performance.
8IBUBMTPDIBOHFTPWFSUJNFJTUIFJNQBDUSFTJTUBODFPGUIF
system. But since an installed system has little opportunity 
to sustain impact, this change has little to no effect. It does 
mean, however, that if a cut-in is necessary as a result of a 
modification to the line or the addition of a fixture, addition-
al care should be taken to prevent the system from sustaining 
JNQBDU8IJMFJUJTBDDFQUBCMFUPVTFBSBUDIFUDVUUFSXIFO
installing new pipe, its use can compress the pipe and cause 
end cracks on aged pipe. For this reason, a ratchet cutter 
should not be used on aged CPVC pipe. Even if the cracks are 
not visible, they can eventually propagate through the fitting 
and cause a leak.
I suggest using either a wheel-type cutter or fine-tooth saw 
when performing a cut-in procedure. Once the pipe is cut, 
continue with standard installation procedures, including 
beveling the pipe and solvent cementing the fitting. Keep in 
mind that if the area is wet as a result of water being inside 
the line, you need to add to the cure time typically required. 
In some cases, the required cure time may be three times as 
MPOH5IBUTXIZJUTWBMVBCMFUPUSZUPESZUIFBSFBBTNVDI
as possible.
Repairs or Modifications to Existing CPVC CTS Systems
(Reprinted from FBC Plumbing Connections, Issue 29, 4Q 2009, written by Steve 
Manis, Technical Manager)
OPODPNCVTUJCMFDBTUJSPO%87QJQJOHTZTUFNTJONVMUJTUPSZ
construction.
Using Plastics for Combustion Gas 
Venting
Charlotte Pipe recommends that inquiries about the suit-
ability of plastic piping systems for venting combustion gas-
ses should be directed to the manufacturer of the water or 
space heating equipment being installed. As stated in the 
*OUFSOBUJPOBM $PEF $PVODJMT *OUFSOBUJPOBM 'VFM (BT $PEF
503.4.1.1:
Plastic Pipe and ttings used to vent appliances shall be 
installed in accordance with the appliance manufacturer’s 
installation instructions.
'VSUIFSNPSFTFWFSBMPG UIF "45. TUBOEBSETBQQMJDBCMFUP
plastic pipe and fittings that Charlotte Pipe manufactures 
include the following note: This standard specification does 
not include requirements for pipe and fittings intended 
to be used to vent combustion gases. 