Specifications
m16
93-IXFMR3/6T-A
Kilovolt Amps
(kVA)
Input Current
Input Voltage
Frequency
Output Current
Output Voltage
Dimensions
Weight
Protection
Features
Ignition Protected
UL, cUL Listed
Strain Relief
Product No.
90 Degree
Strain Relief
Warranty
Notes
3.6 kVA
93-IXFMR3/8I-A 93-IXFMR6T-B 93-IXFMR7/5T-A 93-IXFMR12T-A 93-IXFMR12I-A 93-IXFMR24I-A 93-ISOG2/6-A 93-ISOG2/8-A
3.8 kVA
(International)
6 kVA
7.5 kVA
(International)
12 kVA
12 kVA
(International)
24 kVA
(International)
3.6 kVA 3.8 kVA
30 amps 32/16 amps 50 amps 32/16 amps 50 amps 50 amps 100 amps 30 amps 30/16 amps
120 VAC 120/240 VAC 120 VAC 240 VAC 240 VAC 120/240 VAC
200/208/220/
230/240 VAC
120 VAC 120/240 VAC
60 Hz 50/60 Hz 60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 60 Hz 50/60 Hz
30 amps 32 amps 50 amps 32 amps 50 amps 50 amps 100 amps 30 amps 30/16 amps
120 VAC 110/220 VAC 120 VAC 110/220 VAC 120/240 VAC
120/240 VAC,
104/208 VAC
120 VAC 120/240 VAC
120/240 VAC,
104/208 VAC
10.5”x10.5”x8” 10.5”x10.5”x8” 11.75”x10”x11” 11.75”x10”x11” 16”x15”x12” 16”x15”x12” 18.5”x20.5”x17” 9.65”x10.5"x9" 9.65”x10.5"x9"”
60 lbs. 70 lbs. 200 lbs. 157 lbs. 235 lbs. 235 lbs. 550 lbs. 76 lbs. 79 lbs.
Fully encapsulated components and transformer winding, all units feature separate wiring compartments - one for input, another for output.
Enclosures meet NEMA 3R requirements and are corrosion resistant.
Yes Yes Yes Yes Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes Yes No No
97-001127-A 97-001127-A 97-001120-A 97-001120-A 97-001120-A 97-001120-A 97-001121-A Included Included
Not Available Not Available 97-001755 97-001755 97-001755 97-001755-A 97-001741-0 — —
1-Year 1-Year 1-Year 1-Year 1 Year 1-Year 1-Year 1-Year 1-Year
Marine UL/cUL requires the use of strain reliefs with these units; 90 degree and straight strain reliefs are available.
Product No.
93-IXFMR15I-A
15 kVA
(International)
64 amps
50/60 Hz
64 amps
120/240 VAC
16”x15”x12”
235 lbs.
Yes
Yes
97-001120-A
97-001755-A
1 Year
240 VAC
Isolation transformers isolate the boat from shore, protecting onboard
electrical systems and electronics from potential shore-side hazards.
They also diminish the potential for water shock hazards and eliminate the
need for galvanic isolators and polarity alarms. Isolation transformers
eliminate galvanic current without electronic components, whereas galvanic
isolators use diodes and capacitors to stop current flow. Charles Isolation
Transformers are ruggedly constructed, including a full current carrying
shield, a thick sheet of copper located between the primary (shore) and
secondary (boat) windings of the transformer that must withstand an
isolation test of 4,000 volts.
ISO-G2 Isolation Transformers are a compact alternative to galvanic isolators with status
monitors that require additional space, increase installation time and cost for the boat
builder and do not provide any of the protection from potential shore-side hazards. They
offer better onboard protection, easier installation and a better overall value for your boat
compared to galvanic isolators. 1-year limited manufacturer’s warranty, made in the USA.
Features
• Constructed of lightweight, corrosion-resistant powder coated aluminum
• Built in terminal block and two position installation options for easy wiring.
• Key hole slots allow for easy installation
• Rugged corrosion-resistant components for years of trouble-free
use in the marine environment
• Ignition protected
• Meets all ABYC and USCG standards
Benefits
• Fully isolates the boat from potential shore-side hazards
• Protects onboard electrical equipment and electronics
• Eliminates the need for galvanic isolators and polarity alarms
ISOLATION TRANSFORMERS
Installation Kits
97-ISOKIT36-A Installation kit for 3.6 kVA and 3.8 kVA transformers
97-ISOKIT6-A Installation kit for 6 kVA and 7.5 kVA transformers
97-ISOKIT12-A Installation kit for 12 kVA and 15 kVA transformers
97-ISOKIT24-A Installation kit for 24 kVA transformers
Kits include 10ft of appropriate cable and the appropriate terminals,
circuit breaker and enclosure for the breaker if needed (for US 240
VAC service), and strain reliefs for the circuit breaker enclosure
SoftStart 93-XFMRSOFT-A
Designed to be installed on a boat’s incoming AC shorepower,
SoftStart limits the inrush of AC current to a shoreline transformer to
eliminate the “nuisance” breaker trip when first powering-up a vessel.
May be used with any 50 amp transformer. 120 VAC, 50/60 Hz