User`s guide
Section 360−381−S02
41
8. Open the local ICB software.
9. Perform steps 2−7 above. All alarms should clear, and communication will be established.
12.2 Configure for “Using Facility Data Link” in ESF Format
Step Action
1. Open the ICB software for the remote ICB.
2. Select Settings " Set T1 Parameter to open the primary T1 card parameters.
3. Under Automatic Detect Mode, verify that NO is selected.
4. Under Frame Format, select ESF.
5. Under Remote Control Method, select Using Facility Data Link.
6. Click OK to close the T1 Parameter dialog box. Both the local and the remote ICBs will display AR
(alarm).
7. Open the local ICB software.
8. Perform steps 2−6 above. All alarms should clear, and communication will be established.