User`s guide
Section 360−381−S02
16
5.3.2. FXS Parameters (for 3657-80 12 Channel FXS/DPO Unit)
Figure 9. FXS Parameter Settings
Parameter Possible Choices Description
Channel Selection 1−12 (if in Card 1 slot) Select the channel the parameters will be applied to.
Each channel can be configured individually
13−24 (if in Card 2 slot)
Each channel can be configured individually.
25−30 (if in half-size slot)
Channel Impedance 600 ohms Loop matching impedance
900 ohms
Ring Mode interrupted, burst or contin-
uous
This option is available only if PLARD D3 or D4 is se-
lected.
Channel Type FXS/GS Ground start
FXS/LS Loop start
PLARD/D3 Private line automatic ringdown, D3 signaling format.
PLARD/D4 Private line automatic ringdown, D4 signaling format.
MEGACOM/GS/immediate AT&T Megacom—ground start
MEGACOM/GS/wink
MEGACOM/LS AT&T Megacom—loop start
DPO Dial pulse originate
Forced Busy ON or OFF Select ON to force local channel busy
CGA Immediate Idle or Busy CGA immediate conditioning
CGA Delayed Idle or Busy CGA conditioning after alarm delay
TTLP Level (dBm) −10.0 to +6.0 dBm Transmit TLP level
RTLP Level (dBm) −15.0 to +1.0 dBm Receive TLP level