User`s guide
Section 360−381−S02
14
Parameter Possible Choices Description
LBO (Line Build-
Out)
Short Haul: 0 to 660 ft. Pre-equalization of signal for line conditions.
Out)
Long Haul: 0, 7.5, 15, or
22.5 dB
Receive gain control for span line attenuation.
Bypass Mode auto bypass When this option is enabled, the T1 connected to the T1−S is
automatically bypassed or connected to the T1 connected to
the ST1U span when one of the following conditions occurs:
power is lost to the ICB, the T1−S or the ST1U card fails.
forced no bypass When this option is enabled, the T1 connected to the T1−S is
not bypassed or connected to the T1 connected to the ST1U
when power is lost or there is a card failure. The timeslot al-
locations remain assigned for the ICB but connections on any
of the “pass through” timeslot assignments are broken if power
is lost or there is a card failure in the ICB.
Bypass button
(manual override
forcing bypass)
If this function is selected from the NMS or craft interface, the ICB will immediately go into
T1 bypass. If the ICB was being managed over a T1, control will be lost and the manage-
ment screen for that ICB will log out. Re-login is only possible through the craft interface or
through a local connection to the ICB’s rear NMS interface. Restoring normal error-free op-
eration will require removing both the T1−S and ST1U cards. The cards must then be rein-
serted in order, first the T1−S and then the ST1U.
Remote Control
Method (to the
None No communication to remote unit (non-Charles Industries unit)
Method (to the
remote ICB
)
Occupy One Channel One 64K channel is used for communication.
remote ICB)
Using Facility Data Links Communication to remote over FDL (ESF mode only)
Frame Format SF Superframe format
ESF Extended Superframe format
Line Code AMI Alternate mark inversion
B8ZS Bit 8 zero suppression
5.3 Set Card Parameters
Parameters available on these dialog boxes will depend upon the cards you use.
Once you have finished configuring the card, click OK to activate the new settings, and click Close to close the
dialog box. To cancel changes without saving, click Close.
Note: For complete descriptions of the card parameters, refer to documentation for the individual cards you are
using.