User`s guide

Section 360381S02
12
5.1 Set T1 Parameter
Select Settings"Set T1 Parameter to open the primary T1 card (T1-S) parameter settings.
Once you have finished configuring the card, click OK to activate the new settings, and click Close to close the
dialog box. To cancel changes without saving, click Close.
Figure 5. T1 Parameter Settings
Parameter Possible Choices Description
CGA Process
Mode
Normal Carrier group alarm response characteristics per Pub 43801.
Mode
CM2 Carrier group alarm mode 2 (see T1 Controller documentation)
CM3 Carrier group alarm mode 3 (see T1 Controller documentation)
Timing Source Loop Timing Internal clock synchronized to incoming T1 signal.
External Timing Internal clock synchronized to external clock input terminals on
rear panel.
Internal Timing Internal clock selected as master clock.
LBO (Line Build-
Out)
Short Haul: 0 to 660 ft. Pre-equalization of signal for line conditions.
Out)
Long Haul: 0, 7.5, 15, or
22.5 dB
Receive gain control for span line attenuation.
Frame Format SF Superframe format
ESF Extended Superframe format
Line Code AMI Alternate mark inversion
B8ZS Bit 8 zero suppression
Remote Control
Method (to the
None No communication to remote unit (non-Charles unit)
Method (to the
remote ICB
)
Occupy One Channel One 64K channel is used for communication.
remote ICB)
Using Facility Data Links Communication to remote over FDL (ESF format only)
Automatic Detect
Mode
No SF/ESF must be manually selected
Mode
Yes Auto detection of SF/ESF mode, requires loop timing