User`s guide

Section 360381C02
32
FarEnd loopback traps will be generated at the farend equipment.
9. ADDRESSING/SUBNET MASK/GATEWAY//MAC ADDRESS MENU
For the NMS/GUI software (Ethernet GUI) only the IP address and the address ID switch setting of the T1-S card
are required. (The IP address and the community name can only be viewed using the Craft interface.) If a remote
ICB does not require an IP address, use IP address 0.0.0.0 with a subnet of 255.255.255.255.
Only locally managed shelves need to have an IP address set. A locally managed shelf is any ICB that is con-
nected to a manager via an Ethernet LAN regardless of where the shelf is physically located. A remotely-man-
aged shelf is an ICB that is managed over a T1 through a locally managed shelf.
The gateway address is the IP address of the router on the LAN that is located between the shelf and the manag-
er.
See the Network Management Software documentation for GUI addressing.
All remotely managed systems must have a unique address ID switch setting that is different from
the local system’s address ID switch setting and must be greater than zero.
Warning
Figure 28. IP Address/Subnet Mask/MAC Address Menu
Enter the appropriate IP address and subnet mask for the network connected to the ICB. SNMP and Graphical
User Interface Network Management is NOT possible over the Ethernet interface unless a unique IP address is
assigned to the local shelf.