User`s guide
Section 360−381−C02
30
8. SNMP CONFIGURATION
8.1 SNMP Community Table
For SNMP management, the T1-S is addressed using a combination of the following:
IP Address
Community Name
Address ID Switch Setting
A “Reset to Factory Settings” will clear the table configuration. Only locally managed shelves need the SNMP
community table set. A locally managed shelf is any ICB that is connected to a manager via an Ethernet LAN re-
gardless of where the shelf is physically located. A remotely managed shelf is an ICB that is managed over a T1
through a locally managed shelf. The SNMP Network Node Manager documentation provides additional informa-
tion.
Figure 26. SNMP Community Table
Parameter Description
Community Enter the name to be used to refer to this equipment
Privilege Use Read for monitoring and Read/Write for monitoring and provisioning
IP Address Enter the IP address of the SNMP manager
Submask Enter the appropriate subnet mask.
Applying changes to this table will initiate a warm start and momentarily disrupt T1 service.
Warning
Note: New settings must be applied after changes are made to activate the changes to this table.