Installation manual
1 -3
Introduction
Specifications
Electrical Input
SINGLE PORT DUAL PORT
AC Voltage 208/240VAC 208/240VAC
Current Input Power Connection
Required Service
Panel Breaker
Current Input Power Connection
Required Service
Panel Breaker
Standard 30A One 40A branch circuit
40A dual pole
(non-GFCI type)
30A x 2
Two independent 40A branch
circuits
40A dual pole
(non-GFCI type) x 2
Standard Power Share n/a n/a n/a 32A One 40A branch Circuit
40A dual pole
(non-GFCI type)
Power Select 24A 24A One 30A Branch circuit
30A dual pole
(non-GFCI type)
24A x 2
Two independent 30A branch
circuits
30A dual pole
(non-GFCI type) x 2
Power Select 24A
Power Share
n/a n/a n/a 24A One 30A branch circuit
30A dual pole
(non-GFCI type)
Power Select 16A 16A One 20A Branch circuit
20A dual pole
(non-GFCI type)
16A x 2
Two independent 20A branch
circuits
20A dual pole
(non-GFCI type) x 2
Power Select 16A
Power Share
n/a n/a n/a 16A One 20A branch circuit
20A dual pole
(non-GFCI type)
Service Panel GFCI Do not provide external GFCI as it may conflict with internal GFCI (CCID)
Wiring - Standard 3-wire (L1, L2, Earth) 5-wire (L1, L1, L2, L2, Earth)
Wiring - Power Share n/a 3-wire (L1, L2, Earth)
Station Power 8W typical (standby), 15W maximum (operation)
Electrical Output
Standard 7.2kW (240VAC@30A) 7.2kW (240VAC@30A) x 2
Standard Power Share n/a
7.2kW (240VAC@30A) x 1 OR
3.8kW (240VAC@16A) x 2
Power Select 24A 5.8kW (240VAC@24A) 5.8kW (240VAC@24A) x 2
Power Select 24A
Power Share
n/a
5.8kW (240VAC@ 24A) x 1 OR
2.9kW (240VAC@12A) x 2
Power Select 16A 3.8kW (240VAC@16A) 3.8kW (240VAC@16A) x 2
Power Select 16A
Power Share
n/a
3.8kW (240VAC@16A) x 1 OR
1.9kW (240VAC@8A) x 2
Functional Interfaces
Connector(s) Type SAE J1772™ SAE J1772™ x 2
Charging Cable Length 18’ (5.5 meters) 18’ (5.5 meters) x 2
Overhead Cable
Management System
Yes
LCD Display 5.7” full color, 640x480, 30fps full motion video, active matrix, UV protected
Card Reader ISO 15693, 14443, NFC
Locking Holster Yes Yes x 2
Safety and Connectivity Features
Ground Fault Detection 20mA CCID with auto retry
Open Safety Ground Detection Continuously monitors presence of safety (green wire) ground connection
Plug-Out Detection Power terminated per SAE J1772™ specifications
Power Measurement Accuracy +/- 2% from 2% to full scale (30A)
Power Report/Store Interval 15 minute, aligned to hour
Local Area Network 2.4 GHz Wi-Fi (802.11 b/g/n)
Wide Area Network 3G GSM, 3G CDMA
Safety and Operational Ratings
Enclosure Rating Type 3R per UL 50E
Safety Compliance
UL listed for USA and cUL certified for Canada; complies with UL 2594, UL 2231-1, UL 2231-2, and NEC
Article 625
Surge Protection
6kV @ 3000A. In geographic areas subject to frequent thunder storms, supplemental surge
protection at the service panel is recommended.
EMC Compliance FCC Part 15 Class A
Operating Temperature -22°F to 122°F (-30°C to +50°C)
Storage Temperature -40°F to 122°F (-40°C to +50°C)
Operating Humidity up to 85% @ +50°C (122°F) non-condensing
Non-Operating Humidity up to 95% @ +50°C (122°F) non-condensing
Terminal Block Temperature Rating 221°F (105°C)
Maximum Stations per 802.11 Radio Group 10. Each station must be located within 150 feet “line of sight” of a gateway station.