Installation Manual
Table Of Contents
- Front Cover
- Table of Contents
- Introduction
- Installing a Bollard Mount
- Installing a Wall Mount
- Installing the Head and Top Cap
- Preparing the Station for Activation on ChargePoint
- Troubleshooting
- Appendix A: Preparing the Installation Site for a Bollard Mount
- Appendix B: Removing or Replacing the EV Charging Sign
- Appendix C: CT4000 Power Sharing Instructions
- Appendix D: Limited Product Warranty
1 -3
Introduction
Specifications
Electrical Input
Single Port Dual Port
AC Power Input Rating - Standard 208/240VAC 60Hz single phase @ 32A 208/240VAC 60Hz single phase @ 32A x 2
AC Power Input Rating - Power Sharing n/a 208/240 VAC 60Hz single phase @ 32A
Input Power Connections - Standard One 40A branch circuit. Two independent 40A branch circuits.
Input Power Connections - Power Sharing n/a One 40A branch circuit
Required Service Panel Breaker - Standard 40A dual pole (non-GFCI type) 40A dual pole (non-GFCI type) x 2
Required Service Panel Breaker - Power Sharing n/a 40A dual pole (non-GFCI type)
Service Panel GFCI Do not provide external GFCI as it may conflict with internal GFCI (CCID)
Wiring - Standard 3-wire (L1, L2, Earth) 5-wire (L1, L1, L2, L2, Earth)
Wiring - Power Sharing n/a 3-wire (L1, L2, Earth)
Standby Power 15W typical (standby), 20W maximum (operation)
Electrical Output
AC - Standard 7.2kW (240VAC @ 30A) 7.2kW (240VAC @ 30A) x 2
AC - Power Sharing n/a 7.2kW (240VAC @ 30A) x 1 OR
3.8kW (240VAC @ 16A) x 2
Functional Interfaces
Plug(s) Type SAE J1772™ SAE J1772™ x 2
Charging Cable Length 18’ (5.5 meters) 18’ (5.5 meters) x 2
Overhead Cable Management System Yes Yes
Card Reader ISO 15693, 14443, NFC
Locking Holster Yes Yes x 2
Safety and Connectivity Features
Ground Fault Detection 20mA CCID with auto retry
Open Safety Ground Detection Continuously monitors presence of safety (green wire) ground connection
Plug-Out Detection Power terminated per SAE J1772™ specifications
Power Measurement Accuracy +/- 2% from 2% to full scale (32A)
Power Report/Store Interval 15 minute, aligned to hour
Local Area Network 2.4 GHz Wi-Fi (802.11 b/g/n)
Wide Area Network 3G GSM, 3G CDMA
Safety and Operational Ratings
Enclosure Rating Type 3R per UL 50E
Safety Compliance UL listed for USA and cUL certified for Canada; Complies with UL 2594, UL 2231-1,
UL 2231-2, and NEC Article 625
Surge Protection 6kV @ 3000A. In geographic areas subject to frequent thunder storms, supplemental
surge protection at the service panel is recommended.
EMC Compliance FCC Part 15 Class A
Operating Temperature -22°F to 122°F (-30°C to +50°C)
Operating Humidity up to 85% @ +50°C (122°F) non-condensing
Non-operating Humidity up to 95% @ +50°C (122°F) non-condensing
Terminal Block Temperature Rating 221°F (105°C)
Maximum Charging Stations per 802.11 Radio
Group
10. Each station must be located within 150 feet “line of sight” of a gateway station.
ChargePoint, Inc. reserves the right to alter product offerings and specifications at any time without notice, and is not responsible for typographical or graphical
errors that may appear in this document.