Installation Manual

Table Of Contents
A-2
Install J-Bolts and conduit into concrete as illustrated. To
ensure correct alignment, use the template stapled into the
center fold of this document (illustrated below).
IMPORTANT:
The concrete block must measure at least 24” (61 cm)
on all sides. Check local codes to ensure compliance.
The J-Bolts threads must extend at least 2 ½” (6.4 cm)
above the concrete and 9” (23 cm) below the concrete.
The conduit must extend 12” to 24” (30 to 61 cm)
above the concrete. Check local codes to ensure
compliance.
You can also print a PDF version of the mounting
template, available at www.chargepoint.com/support-
installation-guides.php. Before using a self-printed
template, print at full scale on 11” x 17” paper and verify
at least one dimension.
Example of template (not to scale):
Conduit must extend
12-24” (30-61 cm) above
the concrete. Check local
codes.
J-Bolts must extend at
least 2 ½” (6.4 cm)
above the concrete and
9” (23 cm) below the
concrete.
Concrete block should
extend no more than 2”
(50 mm) above grade.