Cut Sheet
chargepoint.com 5
Safety and Connectivity Features
Ground Fault Detection 20 mA CCID with auto retry
Open Safety Ground Detection Continuously monitors presence of safety (green wire) ground connection
Plug-Out Detection Power terminated per SAE J1772™ specifications
Power Measurement Accuracy +/- 2% from 2% to full scale (30A)
Power Report/Store Interval 15 minute, aligned to hour
Local Area Network 2.4 GHz WiFi (802.11 b/g/n)
Wide Area Network LTE Category 4
Safety and Operational Ratings
Enclosure Rating Type 3R per UL 50E
Safety Compliance UL listed and cUL certified; complies with UL 2594, UL 2231-1, UL2231-2, and NEC Article 625
Surge Protection 6 kV @ 3,000A. In geographic areas subject to frequent thunderstorms, supplemental surge
protection at the service panel is recommended
EMC Compliance FCC Part 15 Class A
Operating Temperature -40°C to 50°C (-40°F to 122°F)
Storage Temperature -40°C to 60°C (-40°F to 140°F)
Non-Operating Temperature -40°C to 60°C (-40°F to 140°F)
Operating Humidity Up to 85% @ 50°C (122°F) non-condensing
Non-Operating Humidity Up to 95% @ 50°C (122°F) non-condensing
Terminal Block Temperature Rating 105°C (221°F)
Network All stations include integral LTE modem
ChargePoint, Inc. reserves the right to alter product oerings and specifications at any time without notice, and is not responsible for typographical or graphical errors that may
appear in this document.