Instruction manual

77
Resolution: Sets the resolution for the recordings. The set value applies to all channels.
Frame Rate: Sets the recording rate.
Quality: Sets the image quality in 5 levels.
Recording: Sets the recording mode.
Sensor Recording: Sensor recording is performed when an external sensor signal is input to the specified
external sensor input terminal.
Pre Record: Sets whether to perform or not pre recording.
Post Event Record: Sets the duration of the event recording.
Audio: Sets whether to perform or not audio recording.
Schedule: Sets the schedule for schedule recording. None: Gray, Continuous: Green, Motion: Yellow,
Sensor: Red
SUBMIT: Save surely by pressing this button after setting the value.
9-7-3. Device
Select Device to set the motion zone, sensor input/alarm output conditions, PTZ control and spot setting
conditions.
9-7-3-1. Device
Setting the motion zone/Sensitivity: Select the zone where the motion sensor is active. It is necessary to
set a detection frame when PARTIAL ZONE is selected. Select the level of detection sensitivity of the
motion sensor. Sensitivity selections: 1~9(High sensitivity level)
Partial Zone: If selecting Partial Zone, a button is displayed to the right. Click the button and click(or drag)a
grid cell in the desired detection frame.
Key Tone: Sets On or Off of Key Tone.
Remote Controller ID: Sets an ID number on the supplied remote control for its identification.