Specifications

Channel Master Operation Manual
P/N 95B-6001-00 (January 2005) page 59
EX – Coordinate Transformation
Purpose Sets the coordinate transformation processing flags.
Format EXnnnnn
Range Firmware switches (see description)
Default EX01010
Recommended Setting. The default setting for this command is
recommended for most applications.
Description EX sets firmware switches that control the coordinate trans-
formation processing for velocity and percent-good data.
Table 12: Coordinate Transformation Processing Flags
Setting Description
EX00010 Radial beam coordinates, I.E., 1, 2. Pitch/Roll not applied.
EX01010 Instrument coordinates. X, Y vectors relative to the Channel Master.
Pitch/Roll not applied.
NOTE. Bit 2 is reserved, and must be set to one for the Channel Master
systems to get any velocity solution.