taken at the transducer head. See the primer for information
on speed of sound calculations.
Note If the EZ Transducer Depth field = 1, the Channel Master
overrides the manually set ED value and uses depth from the
internal pressure sensor. If a pressure sensor is not available,
the Channel Master uses the manual ED setting.
EP - Pitch (Tilt 1)
Purpose Sets the Channel Master pitch (tilt 1) angle.
Format EP±nnnn
Range ±nnnn = -179.00 to +180.00 degrees (in 100
th
of degrees)
Recommended Setting. Use the EZ-command.
Description EP sets the Channel Master pitch (tilt 1) angle.
Example Convert pitch values of +14 and -3.5 to EP-command values.
EP = 14.00 × 100 = 1400 = EP01400 (+ is understood)
EP = -3.50 × 100 = -350 = EP-00350
Note If the EZ command Pitch field = 1, the Channel Master over-
rides the manually set EP value and uses pitch from the trans-
ducer’s internal tilt sensor. If the sensor is not available, the
Channel Master uses the manual EP setting.
ER - Roll (Tilt 2)
Purpose Sets the Channel Master roll (tilt 2) angle.
Format ER±nnnn
Range ±nnnn = -179.00 to +180.00 degrees (in 100
th
of degrees)
Recommended Setting. Use the EZ-command.
Description ER sets the Channel Master roll (tilt 2) angle.
Example Convert roll values of +14 and -3.5 to ER-command values.
ER = 14.00 × 100 = 1400 = ER01400 (+ is understood)
ER = -3.50 × 100 = -350 = ER-00350
Note If the EZ command Roll field = 1, the Channel Master over-
rides the manually set ER value and uses roll from the trans-
ducer’s internal tilt sensor. If the sensor is not available, the
Channel Master uses the manual ER setting.