Specifications
Channel Master Operation Manual
P/N 95B-6001-00 (February 2006) page 65
ID - Diameter
Purpose Sets the diameter of a circular channel.
Format ID n.nnn
Range 0.5 to 100 meters
Default ID 1.000
Recommended Setting. Set using WinHADCP.
Description The ID commands sets the diameter of a circular channel in
meters. Diameters from 0.5 to 100 meters are allowed.
IE - Transducer Elevation
Purpose Sets the mounting elevation of the Channel Master.
Format IE m.mmm, n.nnn
Range m = 0 to 5000 meters, n = -100 to 5000 meters
Default IE 1.000, 0.000
Recommended Setting. Set using WinHADCP.
Description the first value is the mounting elevation of the Channel Mas-
ter. The second value is the elevation of the bottom of the
channel (for circular, trapezoidal and rectangular channels).
Both values are in meters. The range of allowed values for the
first parameter is 0 to 5000 meters and the allowed range for
the second parameter is -100 to 5000 meters.
IP - XY pairs
Purpose Used to provide the geometric details of the channel shape for
an arbitrary channel.
Format IP n, x.xxx, y.yyy
Range n = 1 to 99, x = 1 to 9998, y = 1 to 9998 (IP0 = help)
Default N/A
Recommended Setting. Set using WinHADCP.
Description The initial position command is a list of up to 99 x, y pairs
describing the cross-section of the bottom of the channel. The
first value ānā is the number of the coordinate pair in order
from one side to the other. The next two values are the hori-
zontal distance across the channel and then the elevation of the
bottom at that distance. To end the list enter 9999, 9999 for x
and y. Entries below this are disregarded. Each n, x, y triplet