Specifications
Channel Master Operation Manual
page 56 Teledyne RD Instruments
CL - Battery Saver Mode
Purpose Determines whether the Channel Master will attempt to con-
serve power.
Format CLn
Range n = 0 to 1 (0 = do not conserve power, 1 = conserve power)
Default CL1
Recommended Setting. The default setting for this command is
recommended for most applications.
Description CL0 means the ADCP will not make any attempt to conserve
power. Setting the CL command to CL1 means the ADCP
will attempt to conserve power by going to sleep at every op-
portunity.
NOTE. In order for software breaks to work, the CL-command must be set
to CL0.
CR – Retrieve Parameters
Purpose Resets the Channel Master command set to factory or user
settings.
Format CRn
Range n = 0 (User), 1 (Factory)
Recommended Setting. Use as needed.
Description The Channel Master automatically stores the last set of com-
mands used in RAM. The Channel Master will continue to be
configured from RAM unless it receives a CR-command or
until the RAM loses its power.
Table 11: Retrieve Parameters
Format Description
CR0 Loads into RAM the command set last stored in non-volatile memory (user settings) using
the CK-Command.
CR1 Loads into RAM the factory default command set stored in ROM (factory settings).
NOTE. CR keeps the present baud rate and does not
change it to the
value stored in non-volatile memory or ROM. This ensures the Channel
Master maintains communications with the terminal/computer.