Specifications
Channel Master Operation Manual
page 50 Teledyne RD Instruments
10.2 Command Descriptions
Each listing includes the command’s purpose, format, default setting (if ap-
plicable) range, recommended setting, and description. When appropriate,
we include amplifying notes and examples. If a numeric value follows the
command, the Channel Master uses it to set a processing value (time, range,
percentage, processing flags). All measurement values are in metric units
(mm, cm, and dm).
10.2.1 Miscellaneous Commands
? – Help Menus
Purpose Lists the major help groups.
Format x? (see description)
Description Entering ? by itself displays all command groups. To display
help for one command group, enter x?, where x is the com-
mand group you wish to view. When the Channel Master dis-
plays the help for a command group, it also shows the format
and present setting of those commands. To see the help or set-
ting for one command, enter the command followed by a ques-
tion mark. For example, to view the CB-command setting en-
ter CB?.
Examples See below.
>?
Available Commands:
C ---------------------- Control Commands
E ---------------------- Environment Commands
I ---------------------- Index Commands
M ---------------------- Loop Recorder Commands
P ---------------------- Performance Test Commands
S ---------------------- Sensor Commands
T ---------------------- Time Commands
V ---------------------- Vertical Beam Commands
Y ---------------------- Display Banner
W ---------------------- Water Profiling Commands
? ---------------------- Display Main Menu
>C?
Available Commands:
CB 811 ------------------ Serial Port Control {baud;parity;stop}
CF 11110 ---------------- Set Ctrl Flags {e;p;b;s;*}
CJ 0,0,0 ---------------- SDI-12 Configuration {En/Dis,Addr,E/M }
CK ---------------------- Save Command Parameters to Flash
CL 1 -------------------- Sleep Enable ( 1=Enabled, 0=Disabled )
CR ---------------------- Restore Cmd defaults [0=user,1=factory]
CS ---------------------- Start Pinging
CT 0 -------------------- Turnkey (0 = OFF, 1 = ON)
CZ ---------------------- Put the ADCP to sleep.
C? ---------------------- Display C-Command Menu
>
>CB?
CB 811 ------------------ Serial Port Control {baud;parity;stop}
>