Specifications

Channel Master Operation Manual
P/N 95B-6001-00 (February 2006) page 13
6 Testing Your Channel Master
Use the following steps to test the Channel Master.
a. Interconnect and apply power to the system as described in “Setup the
Channel Master,” page 10.
b. Start the BBTalk program (for help on using BBTalk, see the RDI Tools
Users Guide).
c. On the File menu, click Break (you can also press the End key to send
a break or use the Toolbar and press the B button). You should see the
wakeup message appear on the log file window.
Horizontal ADCP
RD Instruments (c) 2005
All rights reserved.
Product Version: CM02.04
>
d. At the “>” prompt in the communication window, enter the direct com-
mand CR1 then press the Enter key. This will set the Channel Master to
the factory default settings.
e. At the “>” prompt in the communication window, enter the direct com-
mand CK then press the Enter key. This will save the factory default
setting.
f. At the “>” prompt in the communication window, enter the direct com-
mand PS0 then press the Enter key. This will display the Channel Mas-
ter system configuration data.
>PS0
Serial Number: 5813
Frequency: 1228800 Hz
Configuration: HADCP: 2-beam velocity + vertical stage.
Transducer Type: PISTON
Beam Angle: 20 Degrees
Beam Pattern: CONVEX
Sensors: TEMP PRESS TILTS
Product Version: CM02.04
CPU Firmware: 28.28f
FPGA Version: 2.00.003
Sensor Boot: 32.02
Sensor Firmware: 33.03
Board Serial Number Data:
24 00 00 00 32 23 40 23 SNS72B-1000-00A
15 00 00 00 31 65 DC 23 PIO72B-2001-00B
A8 00 00 00 10 66 B6 23 XDR71B-1007-00A
E3 00 00 00 1F CD 99 23 PER72B-2006-00X
DC 00 00 00 31 CA 43 23 RCV72B-2003-09A
90 00 00 00 31 AB 7F 23 DSP72B-2002-00A
>