Specifications
Channel Master Operation Manual
page 114 Teledyne RD Instruments
mand has a default of 5000 mm/s. This large WE setting effectively pre-
vents the Channel Master from rejecting data based on error velocity.
FIELD 3 - Percentage of No Solution Transformations - 45% of the velocity
data were rejected because there was insufficient information (velocity
Data) to attempt a transformation.
FIELD 4 - Percentage of Full Solutions - 0% of the velocity data collected
during the ensemble for range cell 60 generated a Full Solution. A Full So-
lution indicates that an error velocity is available. The Channel Master is
not capable of generating Full Solutions because 2-beams do not provide
sufficient information to generate a Full Solution.
Table 23: Percent-Good Data Format
Hex Digit Binary
Byte
Field Description
1-4 1,2 ID Code Stores the percent-good data identification word 0400
(00 04h). LSB is sent first.
5,6 3 Range cell 1,
Field 1
Stores percent-good data for range cell #1, field 1. See above.
7,8 4 Range cell 1,
Field 2
Stores percent-good data for range cell #1, field 2. See above.
9,10 5 Range cell 1,
Field 3
Stores percent-good data for range cell #1, field 3. See above.
11,12 6 Range cell 1,
Field 4
Stores percent-good data for range cell #1, field 4. See above.
13-1028 7-514 Range cell 2 –
255 (if used)
These fields store percent-good data for range cells 2 through
255 (depending on the WN-command), following the same
format as listed above for range cell 1.
These fields contain information about the status and quality of the ADCP
data. A value of 0 means the measurement was good. A value of 1 means
the measurement was bad.
Table 24: Status Data Format
Hex Digit Binary
Byte
Field Description
1-4 1,2 ID Code Stores the percent-good data identification word 0500
(00 04h). LSB is sent first.
5,6 3 Range cell 1,
Field 1
Stores status data for range cell #1, field 1. See above.
7,8 4 Range cell 1,
Field 2
Stores status data for range cell #1, field 2. See above.
9,10 5 Range cell 1,
Field 3
Stores status data for range cell #1, field 3. See above.
11,12 6 Range cell 1,
Field 4
Stores status data for range cell #1, field 4. See above.
13-1028 7-514 Range cell 2 –
255 (if used)
These fields store status data for range cells 2 through 255
(depending on the WN-command), following the same format
as listed above for range cell 1.