User Manual

4
100301 ENGLISH
OPERATION AND PARTS
Paralleling one 2800W-3500W inverter
and one 2000W inverter
1. Inverters to be turned off and all electrical loads
disconnected before installing parallel kit.
2. Align the inverters in the same direction in a “V”
configuration at a minimum of 18 in. [45 cm] apart.
3. Clamp the parallel kit to the left handle of the
inverter on the left of the “V”.
4. Connect the 2800W-3500W inverter.
5. Connect the 2000W inverter by removing the
adapter connectors from the back of the parallel kit.
Remove the connector end cap and insert the RED
power lead into the RED adapter connector and
then into the RED receptacle and the BLACK power
lead into the BLACK adapter connector and then
into the BLACK receptacle.
6. Start engine of both inverters according to inverter
Owner’s Manual. Observe the green output indicator
light on both inverter panels. The light will blink
during start up and will be solid when loads may be
connected.
7. Connect electrical loads to parallel or inverter
panels up to the receptacles rated amperage. Never
exceed the specified capacity of the receptacle.
8. Follow the instructions in the inverter Owner’s
Manual for turning off the inverter.