Owner`s manual

4
Front Panel Controls:
The front panel controls are COMPRESSION, ATK/RLS,
DRIVE, OUTPUT controls as well as RATIO, HPF,
BYPASS, LINK and POWER switches.
General Note: When a toggle switch is positioned toward the label, it is
enabling that function.
The COMPRESSION control sets the compressor
threshold. Turning the knob clockwise increases
compression. The RATIO switch selects between 2:1 and
4:1 ratios.
The DRIVE control sets the drive level to the tube gain
stage, and the OUTPUT control sets the overall output level
of the unit.
Operation is similar to that of a guitar amplifier with
preamp and master volume controls, allowing the amount
of tube saturation to be finely controlled.
The ATK/RLS selector changes both the attack and release
time constants of the compressor. The five attack settings
are 10mS, 22mS, 32mS, 47mS and 70mS. Release times
are proportionately longer and largely program dependant.
The HPF switch activates a 6dB/octave roll off in the
compressor sidechain that is 3dB down at 90Hz.