Wall Mount Wi-Fi® Garage Door Opener Models RJO101 For Residential Use Install On Sectional Doors With Torsion Assemblies Only This product is intended for installation only by trained garage door technicians. This product may require adjustments to door springs and/or track configurations. This product is not intended for use on low headroom tracks with outside pick up drums or garage doors utilizing extension springs.
Table of Contents PREPARATION 2 myQ Serial Number....................................2 Safety Symbol and Signal Word Review....2 Unattended Operation................................2 Planning.....................................................3 Before You Connect with Your Smartphone 4 Preparing Your Garage Door......................5 Tools Needed.............................................5 Carton Inventory........................................6 ADJUSTMENT 7 Identify Door Profile..................
Preparation Planning Survey your area to see if any of the conditions below apply to your installation. Take note of the drum sizes to make sure they are correct. Depending on your requirements, additional materials may be required. THIS DOOR OPENER IS COMPATIBLE WITH: • Doors that use a torsion bar and springs. The torsion bar must be 1" (2.5 cm) diameter. NOT compatible with reverse wound drums. NOTE: Inspect the torsion bar while the door is raised and lowered.
Preparation Before You Connect with Your Smartphone Monitor and control your garage door from anywhere using the myQ app. BEFORE YOU BEGIN: You will need: • Wi-Fi enabled smartphone, tablet or laptop • Broadband Internet Connection • Wi-Fi signal in the garage (2.4 Ghz, 802.11b/g/n required) • Password for your home network (router's main account, not guest network) TEST THE WI-FI SIGNAL STRENGTH Make sure your mobile device is connected to your Wi-Fi network.
Preparation Preparing Your Garage Door BEFORE YOU BEGIN: • Disable locks. • Remove any ropes connected to the garage door. Complete the following test to make sure the garage door is balanced and is not sticking or binding: 1. Lift the door halfway up. Release the door. If balanced, it should stay in place, supported entirely by its springs. 2. Raise and lower the door to check for binding or sticking. 3. A properly balanced door should NOT open or fall rapidly.
Preparation Carton Inventory If anything is missing, carefully check the packing material.
Adjustment 1 Identify Door Profile To identify the door profile number, measure the full drum diameter To prevent possible SERIOUS INJURY or DEATH, follow based on the images below. instructions to select and set door profile for safe and proper NOTE: This step is important to ensure the operation. proper operation of the unit. To view a video demonstration of how to 4-6 inch diameter identify and set the door profile, scan the QR code.
Adjustment 3 Program the Travel Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system. • After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on contact with 1-1/2" (3.8 cm) high object (or 2x4 laid flat) on floor.
Adjustment 5 6 Test the Safety Reversal System Test the Protector System® Without a properly installed safety reversing sensor, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Safety reversal system MUST be tested every month.
Adjustment 7 Test the Power Door Lock 1. With the door fully closed, check to ensure that the power lock bolt is visible protruding through the track. To prevent possible SERIOUS INJURY or DEATH from a falling garage door: • If possible, use emergency release handle to disengage door ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
Operation IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH: 1. Read and follow all warnings and instructions. 2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with garage door control push buttons or remote controls. 3. ONLY activate garage door when it can be seen clearly, it is properly adjusted, and there are no obstructions to door travel. 4.
Operation Using Your Garage Door Opener FEATURES Your garage door opener is equipped with features to provide you with greater control over your garage door operation. Alert2Close The Alert2Close feature provides a visual and an audible alert that an unattended door is closing. TIMER-TO-CLOSE (TTC) The TTC feature automatically closes the door after a specified time period that can be adjusted using a TTC enabled door control (Multi-Function Wall Control).
Operation Connect With Your Smartphone This WiFi® Garage Door Opener is compatible with up to 16 myQ® enabled accessories that can be controlled using the myQ® app. You will need: • Wi-Fi enabled smartphone, tablet or laptop • Broadband Internet Connection • Wi-Fi signal in the garage (2.4 Ghz, 802.
Operation Using the Door Control SYNCHRONIZE THE DOOR CONTROL To synchronize the door control to the garage door opener, press the push bar until the garage door opener activates (it may take up to 3 presses). Test the door control by pressing the push bar, each press of the push bar will activate the garage door opener.
Operation Using the Door Control (continued) FEATURE HOW TO: LIGHTS: TO CHANGE THE AMOUNT OF TIME THE REMOTE LIGHTS WILL STAY ON: Press the LIGHT button to turn the garage door opener lights on or off. When the lights are turned on they will stay on until the LIGHT button is pressed again, or until the garage door opener is activated. Once the garage door opener is activated the lights will turn off after the specified period of time (the factory setting is 4-1/2 minutes).
Programming Your hand-held remote control (model 950ESTD) has already been programmed to the door control (Motion-Detecting Control Panel) at the factory. Below are instructions for programming additional remote controls, keypads, and myQ® enabled accessories to the door control. REMOTE CONTROL MODEL 940ESTD KEYPAD 1. Press the control panel LEARN button twice, and the red learn LED will turn on. 2. Press the button on the remote control that you wish to operate your garage door. 3.
Programming Program the Smart LED Light Your garage door opener remote light has already been programmed at the factory to operate with your opener. Any additional or replacement remote lights will need to be programmed. PROGRAM A DOOR OPENER TO THE SMART LED LIGHT LEARN Button 1. Press the LEARN button on the light until the green LED comes ON. 2. Press the LEARN button on the door opener. OR On the Smart Control Panel® go to Menu > Program > myQ Accessory. 3.
Programming HomeLink® In the rare case the HomeLink system does not program with the Security+ 2.0 Garage door opener, install a repeater kit. Refer to HomeLink instructions below. HomeLink is the in-vehicle system. The image used is for reference only and your product may look different. WHEN TO INSTALL A HOMELINK REPEATER KIT HomeLink I II III All 2006 and Older vehicles – A repeater kit is required and must be purchased by the homeowner.
Maintenance Care of Your Garage Door Opener MAINTENANCE SCHEDULE EVERY MONTH • Manually operate door. If it is unbalanced or binding, call a trained door systems technician. • Check to be sure door opens and closes fully. Adjust limits if necessary (see Adjustment Step 1). • Repeat the safety reversal test. Make any necessary adjustments (see Adjustment Step 2). EVERY YEAR • Oil door rollers, bearings and hinges. The garage door opener does not require additional lubrication.
Troubleshooting Diagnostic Chart UP Button Your garage door opener is programmed with self-diagnostic capabilities. The UP and DOWN arrows on the garage door opener blink the diagnostic codes. DOWN Button DIAGNOSTIC CODE SYMPTOM Up Arrow Down Arrow Blink(s) Blink(s) 1 1 The garage door opener will not close. SOLUTION Safety sensors are not installed, connected or wires may be cut. Inspect sensor wires for a disconnected or cut wire. 1 2 The garage door opener will not close.
Troubleshooting Additional Troubleshooting The garage door opener doesn't operate from either the door control or the remote control: • Does the garage door opener have electric power? Plug a lamp into the outlet. If it doesn't light, check the fuse box or the circuit breaker. (Some outlets are controlled by a wall switch.) • Have you disabled all door locks? Review installation instruction warnings on page 8. • Are the wiring connections correct? Review Installation Step 5.
Troubleshooting Additional Troubleshooting (Continued) • Use the emergency release handle to disconnect the door. The door can be opened and closed manually. When power is restored, pull manual release a second time. • When in Battery Backup mode, the opener should be able to operate up to 20 times. • Disable any door locks. Use the emergency release handle to disconnect the door. The door can be opened and closed manually. When power is restored, pull manual release a second time.
Repair Parts Installation Parts 4 2 1 3 KEY NO. PART NO. 1 041A4582 Emergency release rope and handle assembly 041B4494-1 2-Conductor bell wire - white and white/red 041-0136 Safety Reversing Sensor kit (receiving and sending sensors) with 2-conductor bell wire attached 2 3 6 5 DESCRIPTION 23 KEY NO. PART NO.
Repair Parts Garage Door Opener Assembly Parts 6 5 2 1 3 4 KEY NO. PART NO. DESCRIPTION KEY NO. PART NO. 1 2 3 4 041DJ003MC 041B8861 041C0296 041D1624-2 Logic board Travel module with wire harness Transformer Motor 5 6 041D0190 041-0407-000 041-0408-000 DESCRIPTION Power cord Cover NOT SHOWN Battery door and logic board door Contact Information STOP! This garage door opener WILL NOT work until the safety reversing sensors are properly installed and aligned.
Accessories Explore accessories and replacement parts at www.Chamberlain.com. G953EV G940EV-P2 Wireless Keypad: LOCK 3-Button Remote Control: LIGHT For use outside of the home to enable access to the garage using a 4-digit PIN. Works with ALL Chamberlain openers from 1993-present. myQ® compatible. Includes visor clip. G956EV ENROLL SEND CLOSED ENROLL PASS FAIL READY RETRY Keychain Remote Control Works with ALL Chamberlain openers from 1993-present. myQ® compatible. With key ring.
Warranty CHAMBERLAIN LIMITED WARRANTY Chamberlain Group (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is originally installed, that it is free from defects in materials and/or workmanship for a specific period of time as defined below (the “Warranty Period”). The warranty period commences from the date of purchase.
Automatic Garage Door Opener Safety & Maintenance Guide Garage Door Opener Safety – An Automatic Decision A garage door is the largest moving object in the home. An improperly adjusted garage door and opener can exert deadly force when the door closes – which could lead to entrapment of children or adults and subsequent injury or death. Proper installation, operation, maintenance, and testing of the garage door and automatic opener are necessary to provide a safe, trouble-free system.
Routine Maintenance Can Prevent Tragedies Make monthly inspection and testing of your garage door and opener system a part of your regular routine. Review your owner’s manual for both the door and door opener. If you don’t have the owner’s manuals, contact the manufacturer(s) and request a copy for your specific model(s). Look for the opener model number on the back of the power unit. WARNING – Springs are under high tension. Only qualified individuals should adjust them.