Installation manual for swing gate operators

18
10. TECHNICAL DATA
CHLA250EVC
Input Voltage VAC 220-240
Input frequency Hz 50/60
Motor Voltage VDC 24V
Standby consumption
(without accessories)
W 3.7
Motor Rated Power
(CHLA250EVC = 2 x CHLA250-24)
W 100
Rated Force N 800
Maximum Motor Pushing/Pulling Force N 1250
Cycles per hour 5
Max. cyles per day 20
Max. wing weight m / kg
1.5m / 200kg
2m / 150kg
2.5m / 100Kg
Max. opening angle 110°
Time to open to 90° s 15-18
Piston /Screw travel length mm 300
Cable length m 1.5
End Limit System Encoder with hard stops
Operating Radio Frequency
Sending power
MHz
RX 433MHz (433.30MHz, 433.92MHz, 434.54MHz)
RX 868MHz (868.30MHz, 868.95MHz, 869.85MHz)
TX 865.125MHz, 865.829MHz, 866.587MHz
<10mW
Code Security+ 2.0
Max. nr of remotes 180
Max. nr. of keypads 4
Max. nr. of myQ devices 16
External accessory power 24VDC - max. 500mA
Flahing lamp connector 24VDC - max. 500mA
E-Lock /Magnetic lock conenctor 24VDC - max. 500mA
External relay 24VDC - max. 500mA
Safety edge 8,2 kOhm
Max. nr. of IRs 3
Max. nr. of external inputs 3
Battery back-up unit 2 x 12V, 2.2Ah SKU 490EV
Ingress protection Motor IP 44
Ingress protection control board IP 65
Noise Level dB < 70 db(A)
Working temperature °C -20°C to +55°C
Weight (kit) Kg 19,6
Transmitter Frequency
TX4REV-F
868MHz (868.30MHz, 868.95MHz, 869.85MHz)
Sending power <10mW
Battery CR2032 3V