Instructions / Assembly
Table Of Contents
- ENGLISH
- BILT Intelligent Instructions
- Contents
- Safety Symbol and Signal Word Review
- Unattended Operation
- Preparation
- Assembly
- Installation
- STEP1 Determine the Header Bracket Location
- STEP 2 Install the Header Bracket
- STEP 3 Attach the Rail to the Header Bracket
- STEP 4 Position the Garage Door Opener
- STEP 5 Hang the Garage Door Opener
- STEP 6 Attach the Emergency Release Rope and Handle
- STEP 7 Install the Door Bracket
- STEP 8 Connect the Door Arm to the Trolley
- STEP 9 Install the Door Control
- STEP 10 Wire the Door Control to the Garage Door Opener
- STEP 11 Attach the Warning Labels
- STEP 12 Install the Protector System®
- STEP 13 Wire the Safety Reversing Sensors
- STEP 14 Connect Power
- STEP 15 Align the Safety Reversing Sensors
- Adjustments
- Battery Backup
- myQ® App Control
- Camera
- Operation
- Maintenance
- Troubleshooting
- Warranty
- Contact Information
- Repair Parts
WARNING
30
To prevent possible SERIOUS INJURY or DEATH from electrocution or re:
Be sure power is NOT connected to the opener, and disconnect power to circuit BEFORE
removing cover to establish permanent wiring connection.
Garage door installation and wiring MUST be in compliance with ALL local electrical and
building codes.
NEVER use an extension cord, 2-wire adapter, or change plug in ANY way to make it t
outlet. Be sure the opener is grounded.
To avoid installation difficulties, do not run the opener at this time.
To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third
grounding pin. This plug will only t into a grounding type outlet. If the plug doesn’t t into the outlet
you have, contact a qualied electrician to install the proper outlet.
Installation
STEP 14 Connect Power
THERE ARE TWO OPTIONS FOR CONNECTING POWER:
OPTION A - TYPICAL WIRING
1. Plug in the garage door opener into a grounded outlet.
2. DO NOT run garage door opener at this time.
OPTION B - PERMANENT WIRING
If permanent wiring is required by your local code, refer to the following procedure. To make a
permanent connection through the 7/8-inch hole in the top of the motor unit (according to local
code):
1. Remove the motor unit cover screws and set the cover aside.
2. Remove the attached 3-prong cord.
3. Connect the black (line) wire to the screw on the brass terminal; the white (neutral) wire to the
screw on the silver terminal; and the ground wire to the green ground screw. The opener must
be grounded.
4. Reinstall the cover.
White Wire
Black Wire
Ground Tab
Green Ground Screw
Ground Wire