Instructions / Assembly
Table Of Contents
- ENGLISH
- Easy step-by-stepinteractive 3D instructions
 - Installation Manual
 - Contents
 - Safety Symbol and Signal Word Review
 - Preparation
 - Assembly
 - Installation
- STEP 1 Determine the Header Bracket Location
 - STEP 2 Install the Header Bracket
 - STEP 3 Attach the Rail to the Header Bracket
 - STEP 4 Position the Garage Door Opener
 - STEP 5 Hang the Garage Door Opener
 - STEP 6 Install the Light Bulbs
 - STEP 7 Attach the Emergency Release Rope and Handle
 - STEP 8 Install the Door Bracket
 - STEP 9 Connect the Door Arm to the Trolley
 - STEP 10 Install the Door Control
 - STEP 11 Wire the Door Control to the Garage Door Opener
 - STEP 12 Attach the Warning Labels
 - STEP 13 Install the Protector System®
 - STEP 14 Wire the Safety Reversing Sensors
 - STEP 15 Connect Power
 - STEP 16 Align the Safety Reversing Sensors
 
 - Adjustments
 - Battery Backup
 - myQ® App Control
 - Operation
 - Maintenance
 - Troubleshooting
 - Warranty
 - Repair Parts
 
 
34
Adjustment
1 - Program the Travel
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY 
INJURED or KILLED by a closing garage door.
l Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal 
system.
l After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on 
contact with 1-1/2" (3.8 cm) high object (or 2x4 laid flat) on floor.
While programming the travel, the UP and DOWN buttons can be used to move the door as needed. The Safety 
Reversing Sensors will be disconnected during the Program the Travel process. During the Automatic Force 
Setup the door will automatically open and close.
1 Press and hold the Adjustment
Button until the UP Button begins to 
flash and/or a beep is heard.
The Safety Reversing Sensors will 
be disconnected during the Program 
the Travel process.
2 Press and hold the UP
Button until the door is in 
the desired UP position.
4 Press and hold the
DOWN button until the
door is in the desired
DOWN position.
3 Once the door is in the desired
UP position press and release the 
Adjustment Button. The garage 
door opener lights will flash twice 
and the DOWN Button will begin to 
flash.
5 Once the door is in the desired DOWN
position press and release the Adjustment
Button. The garage door opener lights will
flash twice. Program the Travel is now
complete. If the garage door opener
lights flash 5 times, then programming
has timed out and the Travel Limits have
not been set. Please restart the Program the Travel process.
2 - Automatic Force Set Up
Once both the up and down positions have been manually set, the Safety Reversing Sensors will reconnect and 
become operational. Then, the opener will enter a force-sensing operation by automatically moving the door open 
and close. The garage door opener will sound an audible and visual alert before automatically opening and 
closing the door. The garage door opener will beep three times, confirming that the Automatic Force Setup 
completed successfully. Adjustment is complete.
If you hear one long beep after the door attempts to move, then the Automatic Force Set Up has not completed 
successfully. Please start over at step 1 of Program the Travel.