12
DOOR BOARD 1 DOOR BOARD 2
Door 1 Door 2
WEIGAND INPUT
PRIMARY
RELAY
AUXILIARY
RELAY
PRIMARY
RELAY
AUXILIARY
RELAY
REQUEST
TO EXIT
WEIGAND
OUTPUT
WEIGAND INPUT
REQUEST
TO EXIT
Door 3 Door 4
WEIGAND INPUT
PRIMARY
RELAY
AUXILIARY
RELAY
PRIMARY
RELAY
AUXILIARY
RELAY
WEIGAND INPUT
STATUS
STATUS
STATUSSTATUS
NOT USED
REQUEST
TO EXIT
REQUEST
TO EXIT
Door Board Overview
The ACXL has a combination of access control inputs/outputs on the Door Boards that work in conjunction to control up to 4
access points.
INPUT/OUTPUT USED FOR
Wiegand Input
Proximity Readers, RFID Receiver, and Keypads
Request to Exit
External Free Exit Loop Detectors, Push Buttons, and Proximity Sensors
Status
Door Sensors, Supervised Gate Operators, and EOL (End of Line) Wiring
Primary Relay
Gate Operators, Door Strikes, and Maglocks
Auxiliary Relay
Alarm Bypass, Maglocks, and Lights
Wiegand Output
26 Bit Access Granted Activity for integration with third party systems
PRE-INSTALL NETWORK PROGRAMMINGINSTALL ACCESS CONTROLINTRODUCTION