User Manual

20
Wiegand Proximity Reader
The controller is designed specifi cally for the HID PROX-POINT+ MINI READER proximity reader to be mounted on the faceplate.
1. Disconnect power.
2. Remove the mounting plate and gasket from the controller.
3. Use a bench vise with soft jaws to hold the mounting plate and
drill a hole for the cable with a 5/16" drill bit.
4. Drill two mounting holes with a 7/64" drill bit. Make the
threads using the self-tapping screws provided with the
HID reader. NOTE: Thread the screw and remove. Clean the
mounting hole thoroughly until the entire thread is made.
5. Reinstall the gasket and mounting plate onto the controller.
6. Install the proximity reader and secure with the screws.
7. Apply silicon around the cable hole.
8. The proximity reader can be wired to any of the 4 Wiegand
Inputs on the door control boards. Insulate any unused wires
from the controller to prevent a short. (Refer to instructions
supplied with your Wiegand device for more information.)
9. Connect power.
10. Refer to LiftMaster Cloud for programming.
PRE-INSTALL NETWORK PROGRAMMINGINSTALL ACCESS CONTROLINTRODUCTION
Gasket
Mounting Plate
Proximity Reader
Mounting
Holes
Cable
Hole
Mounting Plate
ON
WEIGAND
INPUT
brown
orange
white
green
shield
black
red
Card Reader is wired to WEIGAND INPUT
NOTE: The length of the unshielded
card reader wires should be kept to
a minimum to avoid electrical noise.
Use 18-24 AWG