User Manual

17
PRE-INSTALL NETWORK PROGRAMMINGINSTALL ACCESS CONTROLINTRODUCTION
Gate Access (Wired)
Disconnect power BEFORE making electrical connections. Below is an example of a wiring setup for gate access. Gate access can
be wired to Door 1, 2, 3, or 4 on the Door Boards. LiftMaster
®
Security+ 2.0
®
gate operators can also be programmed to communicate
wirelessly instead of using a wired connection (refer to the following page).
NOTE: The length of the unshielded
wires should be kept to a minimum to
avoid electrical noise.
PUSH
BUTTON
GATE OPERATOR
(connect to closed limit switch)
MAGLOCK
RED LED - brown
GREEN LED - orange
DATA 1 - white
DATA 0 - green
SHIELD - shield
GROUND - black
12Vdc - red
not used - yellow
not used - blue
not used - purple
PROXIMITY READER
OR
KEYPAD
OR
EOL (End of Line)
Resistor (1k ohm)
EXTERNAL FREE EXIT
LOOP DETECTOR
For DC Power:
Install a 1N4005
diode or equivalent
Use 18-22 AWG
Model MG1300
Power for Maglock
(Not Provided)
DO NOT use the power
supply for the controller
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) or equivalent
REQUEST TO EXIT
GROUND
STATUS
NORMALLY OPEN
COMMON
COMMON
NORMALLY CLOSED
+
NORMALLY CLOSED
COMMON
OR
DOOR 1, 2, 3, or 4
REQUEST TO EXIT
WEIGAND
STATUS
PRIMARY RELAY
AUXILIARY RELAY
GATE OPERATOR
COMMON
OPEN
NORMALLY OPEN
ALARM BYPASS
LIGHT
NORMALLY OPEN
COMMON
LOAD
LINE
AUXILIARY RELAY
OR
NEUTRAL
LiftMaster
®
Security+ 2.0
®
gate
operators can be programmed
to communicate wirelessly
instead of using a wired
connection. Refer to the
following page.
(Not applicable for wireless gate operator connections.)
RFID RECEIVER
with wiegand output
Power for RFID RECEIVER
(Not Provided)
DO NOT use the power
supply for the controller
NOTE: DO NOT
run high voltage
power within
the ACXL
enclosure.
Isolation
Relay
Low
Voltage
Power
Supply
NOTE: For KPR2000
keypad, wire the pink and
black (ground) wires together.