User's Manual

29
TERMINALS FUNCTIONALITY WIRING EXAMPLE
SBC and COM
Gate command sequence - Open, Stop, Close, Stop, ...
Soft Open ,Soft Close, Soft Stop (maintained switch does not
override external safeties and does not reset alarm condition)
OPEN and COM
Open command - opens a closed gate
Soft open (maintained switch does not override external safeties and
does not reset alarm condition)
If maintained, pauses Timer-to-Close at OPEN limit
Opens a closing gate and holds open an open gate
CLOSE and COM
Close command - closes an open gate
Soft close (maintained switch does not override external safeties and
does not reset alarm condition)
STOP and COM
Stop command - stops a moving gate
Hard stop (maintained switch overrides Open and Close commands
and resets alarm condition)
If maintained, pauses Timer-to-Close at OPEN limit
Overrides an Open or Close command
SBC
OPN
CLS
STP
COM
COM
O
CLOSE
The EYES/EDGE terminals are used for connecting entrapment protection devices. At least one external monitored entrapment protection device is
required prior to gate movement.
Monitored entrapment protection devices should have been installed with the operator at the time of installation.
Only ONE monitored device may be connected to each input. A monitored device sends a pulsed signal to the operator so the operator is aware of
the device. If the operator does not receive the signal from the device indicating it is working properly, it will not run in that direction.
TERMINALS FUNCTIONALITY WIRING EXAMPLE
EYE ONLY and COM
Open or Close Direction Photoelectric Sensors, the functionality is based
on the switch settings (located next to the terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction is
sensed
EYE/EDGE and COM
Open or Close Direction Photoelectric Sensors or Edge Sensor, the
functionality is based on the switch settings (located next to the
terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction is
sensed
EYE/EDGE and COM
Open or Close Direction Photoelectric Sensors or Edge Sensor, the
functionality is based on the switch settings (located next to the
terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction is
sensed
SBC
EYE
ONL Y
EYE/
EDGE
EYE/
EDGE
COM
1
2
3
OPEN
CLOSE
T
SBC
EYE
ONL Y
EYE/
EDGE
EYE/
EDGE
COM
1
2
3
OPEN
CLOSE
WIRE ACCESSORIES TO EXPANSION BOARD
CONTROL STATION
PHOTOELECTRIC SENSORS AND EDGE SENSORS