User Manual
22
Maglock (Optional)
The LOCK and GND connectors on the board are for the MG1300 MAGLOCK
(24V/250 mA). When the maglock is connected, the lock will disengage before the gate opens.
Flashing Light (Optional)
The DCL and GND connectors on the board are for the FA42LM fl ashing light. The fl ashing light will
turn on before the gate opens.
The Photoelectric Sensor (Optional) Connection
The connection for the photoelectric sensor is a normal closed. If the operator is installed without
photoelectric sensors, connect the IR1 terminal to the GND terminal with a jumper and connect the
IR2 terminal to the GND terminal with a jumper, otherwise the operator will not function properly.
The jumpers are installed from the factory. If IR1 or IR2 is used, leave the other pair of terminals
connected with a jumper.
When the beam of a photoelectric sensor IR1 is interrupted by obstacles, the gate will stop and
reverse during closing or stop during opening. IR1 LED on the control board will turn off. When
the beam of a photoelectric sensor IR2 is interrupted by obstacles, the gate leaf will stop in either
direction. IR2 LED on the control board will turn off.
SETTINGS