Opening/Closing Delay Time Setting
Factory default is set at 2 seconds.
The Open/Closing Delay times can be individually set
from 1-4 seconds.
Opening Delay:
1 OFF and 2 OFF = 1 second
1 ON and 2 OFF = 2 seconds
1 OFF and 2 ON = 3 seconds
1 ON and 2 ON = 4 seconds
The minimum delay time is 1 second.
Closing Delay:
3 OFF and 4 OFF = 1 second
3 ON and 4 OFF = 2 seconds
3 OFF and 4 ON = 3 seconds
3 ON and 4 ON = 4 seconds
The minimum delay time is 1 second.
Single Gate Leaf Operation Setting
5 ON = Only MOTO1 operator is available.
5 OFF = Both MOTO1 and MOTO2 operators are available.
Operation Mode Setting
6 ON = The operation mode is :
OPEN-STOP-CLOSE-OPEN
6 OFF = The operation mode is:
OPEN-STOP-CLOSE-STOP-OPEN
Auto Close Time Setting
Factory default for this function is OFF. The time can be set
from 0-105 seconds.
1 = 15s 2 = 30s 3 = 60s
If all the DIP switches are set to the ON position, the auto
closing time is 105 seconds. If all the DIP switches are set
to the OFF position, the gate leaf will not close automatically.