Product data

139707023-003
8. ASCII Port Options
ASCII Port Options LINCS C8.2 Central Control
Port Port Baud Line Flow Stop Data Bits
Number Type Rate Type Control Bits & Parity
ADAA.000 None 19200 Non-Switched XON/XOFF 1.5 7, Even, NC
ADAA.001 Host 9600 Direct XON/XOFF 1 8, None
ADAA.002 Host 9600 Direct XON/XOFF 1 8, None
ADAA.003 Display 9600 Direct XON/XOFF 1 8, None
ADAA.004 Display 9600 Direct XON/XOFF 1 8, None
ADAA.005 Display 9600 Direct XON/XOFF 1 8, None
ADAA.006 Printer 9600 Direct XON/XOFF 1 8, None
ADAA.007 Printer 9600 Direct XON/XOFF 1 8, None
PF: 1-Menu 7-Back 8-Forw 9-Default 10-Done
An ASCII Port Options panel appears for each set of eight ASCII ports. It enables you to
configure the port type (host, display, or printer) and some other communications parameters
for the port.
Port Number
This is the board and connector, referred to as ASCII port number. In this example, ADA
board A (first one).
Port Type
Choose the type of ASCII host or device attached to each port. Options are:
Host
Display
Printer
None
Baud Rate
Check one of the following baud rates for each port:
300
600
1200
2400
4800
9600 (default)
19200
AUTO (for display stations only)
The auto baud/auto parity (AUTO) option allows LINCS to recognize the ASCII display
station’s baud rate and parity, using key input from the user.